Details
- Sensors
- Inductive proximity switch
- 1 KOM
- SCHNEIDER
Technical specifications
Voltage type
DC
Material housing
Other
Rated control supply voltage Us at DC
12 - 48V
Rated control supply voltage Us at AC 60HZ
- - -V
Rated control supply voltage Us at AC 50HZ
- - -V
Type of electric connection
Connector M8
Suitable for safety functions
No
Explosion safety category for dust
None
Length of sensor
-mm
Width sensor
-mm
Explosion safety category for gas
None
Construction type housing
Cylinder, screw-thread
Diameter sensor
-mm
Type of interface
None
Type of interface for safety communication
None
Coating housing
Other
Performance level according to EN ISO 13849-1
None
SIL according to IEC 61508
None
Switching frequency
-Hz
Category according to EN 954-1
1
Number of semiconductor outputs with signalling function
1
Number of protected semiconductor outputs
1
Number of contact energized outputs with signalling function
0
Supply voltage
12 - 48V
Type of switching output
Other
Number of protected contact energized outputs
0
Height of sensor
8mm
With monitoring function downstream switching devices
No
Max. output current at protected output
100mA
Type of switch function
Other
Interference resistance to magnetic fields
Immune against magnetic DC-field
Mechanical mounting condition for sensor
Not flat
Type of actuation
Metallic Target
Switching distance
1.5mm
Compression-resistant
No
Cascadable
No
From same serie
XSPN01122

Details
- Sensors
- Inductive proximity switch
- 1 KOM
- SCHNEIDER
Technical specifications
Voltage type
DC
Material housing
Other
Rated control supply voltage Us at DC
12 .. 48V
Rated control supply voltage Us at AC 60HZ
- .. -V
Rated control supply voltage Us at AC 50HZ
- .. -V
Type of electric connection
Connector M8
Suitable for safety functions
Explosion safety category for dust
None
Length of sensor
-mm
Width sensor
-mm
Explosion safety category for gas
None
Construction type housing
Cylinder, screw-thread
Diameter sensor
-mm
Type of interface
None
Type of interface for safety communication
None
Coating housing
Other
Performance level according to EN ISO 13849-1
None
SIL according to IEC 61508
None
Switching frequency
-Hz
Category according to EN 954-1
1
Number of semiconductor outputs with signalling function
1
Number of protected semiconductor outputs
1
Number of contact energized outputs with signalling function
0
Supply voltage
12 .. 48V
Type of switching output
Other
Number of protected contact energized outputs
0
Height of sensor
8mm
With monitoring function downstream switching devices
Max. output current at protected output
100mA
Type of switch function
Other
Interference resistance to magnetic fields
Immune against magnetic DC-field
Mechanical mounting condition for sensor
Not flat
Type of actuation
Metallic Target
Switching distance
1.5mm
Compression-resistant
Cascadable
From same serie