Details
- Sensors
- Inductive proximity switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Diameter sensor
-mm
Category according to EN 954-1
1
Width sensor
80mm
Switching distance
60mm
Suitable for safety functions
No
Type of switch function
Normally open contact
Length of sensor
40mm
Mechanical mounting condition for sensor
Not flat
Height of sensor
103mm
Type of electric connection
Cable radial
Construction type housing
Special construction
Type of interface
None
Number of protected semiconductor outputs
0
Voltage type
AC/DC
Supply voltage
12 - 24V
With monitoring function downstream switching devices
No
Type of actuation
Metallic Target
Number of protected contact energized outputs
0
Number of semiconductor outputs with signalling function
0
Type of switching output
2-wire
Number of contact energized outputs with signalling function
0
Type of interface for safety communication
None
Performance level according to EN ISO 13849-1
None
SIL according to IEC 61508
None
Coating housing
Other
Cascadable
No
Switching frequency
150Hz
Material housing
Plastic
Compression-resistant
No
Explosion safety category for gas
None
Rated control supply voltage Us at DC
12 - 24V
Interference resistance to magnetic fields
Immune against magnetic DC- and AC-field
Explosion safety category for dust
None
Max. output current at protected output
200mA
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XS8D1A1MAL2

Details
- Sensors
- Inductive proximity switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Diameter sensor
-mm
Category according to EN 954-1
1
Width sensor
80mm
Switching distance
60mm
Suitable for safety functions
Type of switch function
Normally open contact
Length of sensor
40mm
Mechanical mounting condition for sensor
Not flat
Height of sensor
103mm
Type of electric connection
Cable radial
Construction type housing
Special construction
Type of interface
None
Number of protected semiconductor outputs
0
Voltage type
AC/DC
Supply voltage
12 .. 24V
With monitoring function downstream switching devices
Type of actuation
Metallic Target
Number of protected contact energized outputs
0
Number of semiconductor outputs with signalling function
0
Type of switching output
2-wire
Number of contact energized outputs with signalling function
0
Type of interface for safety communication
None
Performance level according to EN ISO 13849-1
None
SIL according to IEC 61508
None
Coating housing
Other
Cascadable
Switching frequency
150Hz
Material housing
Plastic
Compression-resistant
Explosion safety category for gas
None
Rated control supply voltage Us at DC
12 .. 24V
Interference resistance to magnetic fields
Immune against magnetic DC- and AC-field
Explosion safety category for dust
None
Max. output current at protected output
200mA
From same serie