Details
- Sensors
- Inductive proximity switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at DC
- - -V
Diameter sensor
-mm
Category according to EN 954-1
1
Number of semiconductor outputs with signalling function
0
Type of electric connection
Cable radial
Interference resistance to magnetic fields
Immune against magnetic DC- and AC-field
Construction type housing
Special construction
Compression-resistant
No
Length of sensor
15mm
Number of protected semiconductor outputs
0
Mechanical mounting condition for sensor
Not flat
Type of switching output
2-wire
Height of sensor
40mm
Number of protected contact energized outputs
0
Switching distance
25mm
Cascadable
No
Material housing
Plastic
Type of actuation
Metallic Target
Type of interface for safety communication
None
Max. output current at protected output
200mA
Coating housing
Other
Type of interface
None
Suitable for safety functions
No
SIL according to IEC 61508
None
Rated control supply voltage Us at AC 50HZ
24 - 240V
Switching frequency
1000Hz
Rated control supply voltage Us at AC 60HZ
24 - 240V
Width sensor
40mm
Voltage type
AC/DC
Explosion safety category for dust
None
With monitoring function downstream switching devices
No
Performance level according to EN ISO 13849-1
None
Supply voltage
24 - 240V
Explosion safety category for gas
None
Number of contact energized outputs with signalling function
0
Type of switch function
Normally open contact
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XS8C1A1MAL2

Details
- Sensors
- Inductive proximity switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at DC
- .. -V
Diameter sensor
-mm
Category according to EN 954-1
1
Number of semiconductor outputs with signalling function
0
Type of electric connection
Cable radial
Interference resistance to magnetic fields
Immune against magnetic DC- and AC-field
Construction type housing
Special construction
Compression-resistant
Length of sensor
15mm
Number of protected semiconductor outputs
0
Mechanical mounting condition for sensor
Not flat
Type of switching output
2-wire
Height of sensor
40mm
Number of protected contact energized outputs
0
Switching distance
25mm
Cascadable
Material housing
Plastic
Type of actuation
Metallic Target
Type of interface for safety communication
None
Max. output current at protected output
200mA
Coating housing
Other
Type of interface
None
Suitable for safety functions
SIL according to IEC 61508
None
Rated control supply voltage Us at AC 50HZ
24 .. 240V
Switching frequency
1000Hz
Rated control supply voltage Us at AC 60HZ
24 .. 240V
Width sensor
40mm
Voltage type
AC/DC
Explosion safety category for dust
None
With monitoring function downstream switching devices
Performance level according to EN ISO 13849-1
None
Supply voltage
24 .. 240V
Explosion safety category for gas
None
Number of contact energized outputs with signalling function
0
Type of switch function
Normally open contact
From same serie