Details
- Sensors
- Inductive proximity switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Height of sensor
-mm
Width sensor
-mm
Category according to EN 954-1
1
Length of sensor
60mm
Diameter sensor
18mm
Type of electric connection
Cable radial
Number of protected semiconductor outputs
1
Type of switching output
NPN/NPN
Coating housing
Nickel-plated
SIL according to IEC 61508
None
Type of interface
None
Type of actuation
Metallic Target
Number of semiconductor outputs with signalling function
1
Suitable for safety functions
No
Switching distance
12mm
Max. output current at protected output
200mA
Rated control supply voltage Us at DC
12 - 48V
Number of contact energized outputs with signalling function
0
Construction type housing
Cylinder, screw-thread
Voltage type
AC/DC
Performance level according to EN ISO 13849-1
None
Type of switch function
Normally open contact
Number of protected contact energized outputs
0
Supply voltage
12 - 48V
Mechanical mounting condition for sensor
Not flat
Cascadable
No
Type of interface for safety communication
None
Explosion safety category for gas
None
Interference resistance to magnetic fields
Immune against magnetic DC-field
Material housing
Metal
Explosion safety category for dust
None
With monitoring function downstream switching devices
No
Compression-resistant
No
Switching frequency
1000Hz
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XS618B4NAL5

Details
- Sensors
- Inductive proximity switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Height of sensor
-mm
Width sensor
-mm
Category according to EN 954-1
1
Length of sensor
60mm
Diameter sensor
18mm
Type of electric connection
Cable radial
Number of protected semiconductor outputs
1
Type of switching output
NPN/NPN
Coating housing
Nickel-plated
SIL according to IEC 61508
None
Type of interface
None
Type of actuation
Metallic Target
Number of semiconductor outputs with signalling function
1
Suitable for safety functions
Switching distance
12mm
Max. output current at protected output
200mA
Rated control supply voltage Us at DC
12 .. 48V
Number of contact energized outputs with signalling function
0
Construction type housing
Cylinder, screw-thread
Voltage type
AC/DC
Performance level according to EN ISO 13849-1
None
Type of switch function
Normally open contact
Number of protected contact energized outputs
0
Supply voltage
12 .. 48V
Mechanical mounting condition for sensor
Not flat
Cascadable
Type of interface for safety communication
None
Explosion safety category for gas
None
Interference resistance to magnetic fields
Immune against magnetic DC-field
Material housing
Metal
Explosion safety category for dust
None
With monitoring function downstream switching devices
Compression-resistant
Switching frequency
1000Hz
From same serie