Details
- Sensors
- Inductive proximity switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Height of sensor
-mm
Width sensor
-mm
Category according to EN 954-1
1
Length of sensor
60mm
Diameter sensor
18mm
Type of actuation
Metallic Target
Number of protected semiconductor outputs
1
Number of protected contact energized outputs
0
SIL according to IEC 61508
None
Performance level according to EN ISO 13849-1
None
Switching frequency
1000Hz
Construction type housing
Cylinder, screw-thread
With monitoring function downstream switching devices
No
Explosion safety category for dust
None
Interference resistance to magnetic fields
Immune against magnetic DC-field
Mechanical mounting condition for sensor
Concise
Type of interface
None
Type of switching output
NPN/NPN
Type of electric connection
Cable radial
Supply voltage
12 - 48V
Number of semiconductor outputs with signalling function
1
Number of contact energized outputs with signalling function
0
Coating housing
Nickel-plated
Cascadable
No
Max. output current at protected output
200mA
Type of interface for safety communication
None
Rated control supply voltage Us at DC
12 - 48V
Compression-resistant
No
Voltage type
AC/DC
Type of switch function
Normally open contact
Explosion safety category for gas
None
Material housing
Metal
Switching distance
8mm
Suitable for safety functions
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XS618B1NAL5

Details
- Sensors
- Inductive proximity switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Height of sensor
-mm
Width sensor
-mm
Category according to EN 954-1
1
Length of sensor
60mm
Diameter sensor
18mm
Type of actuation
Metallic Target
Number of protected semiconductor outputs
1
Number of protected contact energized outputs
0
SIL according to IEC 61508
None
Performance level according to EN ISO 13849-1
None
Switching frequency
1000Hz
Construction type housing
Cylinder, screw-thread
With monitoring function downstream switching devices
Explosion safety category for dust
None
Interference resistance to magnetic fields
Immune against magnetic DC-field
Mechanical mounting condition for sensor
Concise
Type of interface
None
Type of switching output
NPN/NPN
Type of electric connection
Cable radial
Supply voltage
12 .. 48V
Number of semiconductor outputs with signalling function
1
Number of contact energized outputs with signalling function
0
Coating housing
Nickel-plated
Cascadable
Max. output current at protected output
200mA
Type of interface for safety communication
None
Rated control supply voltage Us at DC
12 .. 48V
Compression-resistant
Voltage type
AC/DC
Type of switch function
Normally open contact
Explosion safety category for gas
None
Material housing
Metal
Switching distance
8mm
Suitable for safety functions
From same serie