- Sensors
- Inductive proximity switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 60HZ
- - -V
Rated control supply voltage Us at AC 50HZ
- - -V
Height of sensor
-mm
Width sensor
-mm
Category according to EN 954-1
1
Mechanical mounting condition for sensor
Concise
Length of sensor
42.6mm
Number of contact energized outputs with signalling function
0
Coating housing
Nickel-plated
Type of actuation
Metallic Target
Suitable for safety functions
No
Diameter sensor
30mm
Number of protected contact energized outputs
0
Type of switching output
NPN/NPN
Type of switch function
Breaker contact
Type of electric connection
Cable radial
Cascadable
No
Switching distance
10mm
Number of semiconductor outputs with signalling function
1
Explosion safety category for dust
None
Interference resistance to magnetic fields
Immune against magnetic DC-field
Number of protected semiconductor outputs
1
Construction type housing
Cylinder, screw-thread
Explosion safety category for gas
None
Performance level according to EN ISO 13849-1
None
Type of interface
None
SIL according to IEC 61508
None
With monitoring function downstream switching devices
No
Material housing
Metal
Compression-resistant
No
Rated control supply voltage Us at DC
12 - 24V
Max. output current at protected output
200mA
Type of interface for safety communication
None
Voltage type
AC/DC
Switching frequency
1000Hz
Supply voltage
12 - 24V
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XS530B1NBL2

Details
- Sensors
- Inductive proximity switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 60HZ
- .. -V
Rated control supply voltage Us at AC 50HZ
- .. -V
Height of sensor
-mm
Width sensor
-mm
Category according to EN 954-1
1
Mechanical mounting condition for sensor
Concise
Length of sensor
42.6mm
Number of contact energized outputs with signalling function
0
Coating housing
Nickel-plated
Type of actuation
Metallic Target
Suitable for safety functions
Diameter sensor
30mm
Number of protected contact energized outputs
0
Type of switching output
NPN/NPN
Type of switch function
Breaker contact
Type of electric connection
Cable radial
Cascadable
Switching distance
10mm
Number of semiconductor outputs with signalling function
1
Explosion safety category for dust
None
Interference resistance to magnetic fields
Immune against magnetic DC-field
Number of protected semiconductor outputs
1
Construction type housing
Cylinder, screw-thread
Explosion safety category for gas
None
Performance level according to EN ISO 13849-1
None
Type of interface
None
SIL according to IEC 61508
None
With monitoring function downstream switching devices
Material housing
Metal
Compression-resistant
Rated control supply voltage Us at DC
12 .. 24V
Max. output current at protected output
200mA
Type of interface for safety communication
None
Voltage type
AC/DC
Switching frequency
1000Hz
Supply voltage
12 .. 24V
From same serie