Details
- Sensors
- Inductive proximity switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 60HZ
- - -V
Rated control supply voltage Us at AC 50HZ
- - -V
Height of sensor
18mm
Width sensor
-mm
Category according to EN 954-1
1
Diameter sensor
18mm
Length of sensor
61mm
Number of protected semiconductor outputs
1
Type of actuation
Metallic Target
Coating housing
Other
Cascadable
No
SIL according to IEC 61508
None
Voltage type
AC/DC
Max. output current at protected output
200mA
Supply voltage
12 - 24V
Type of interface
None
Mechanical mounting condition for sensor
Not flat
Type of switching output
PNP/PNP
Switching frequency
1000Hz
Rated control supply voltage Us at DC
12 - 24V
Switching distance
12mm
Construction type housing
Cylinder plain
Number of protected contact energized outputs
0
Type of switch function
Normally open contact
Suitable for safety functions
No
Type of interface for safety communication
None
Number of semiconductor outputs with signalling function
1
Number of contact energized outputs with signalling function
0
Type of electric connection
Connector M12
Performance level according to EN ISO 13849-1
None
With monitoring function downstream switching devices
No
Explosion safety category for gas
None
Compression-resistant
No
Explosion safety category for dust
None
Interference resistance to magnetic fields
Immune against magnetic DC-field
Material housing
Metal
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XS2L2SAPAM12

Details
- Sensors
- Inductive proximity switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 60HZ
- .. -V
Rated control supply voltage Us at AC 50HZ
- .. -V
Height of sensor
18mm
Width sensor
-mm
Category according to EN 954-1
1
Diameter sensor
18mm
Length of sensor
61mm
Number of protected semiconductor outputs
1
Type of actuation
Metallic Target
Coating housing
Other
Cascadable
SIL according to IEC 61508
None
Voltage type
AC/DC
Max. output current at protected output
200mA
Supply voltage
12 .. 24V
Type of interface
None
Mechanical mounting condition for sensor
Not flat
Type of switching output
PNP/PNP
Switching frequency
1000Hz
Rated control supply voltage Us at DC
12 .. 24V
Switching distance
12mm
Construction type housing
Cylinder plain
Number of protected contact energized outputs
0
Type of switch function
Normally open contact
Suitable for safety functions
Type of interface for safety communication
None
Number of semiconductor outputs with signalling function
1
Number of contact energized outputs with signalling function
0
Type of electric connection
Connector M12
Performance level according to EN ISO 13849-1
None
With monitoring function downstream switching devices
Explosion safety category for gas
None
Compression-resistant
Explosion safety category for dust
None
Interference resistance to magnetic fields
Immune against magnetic DC-field
Material housing
Metal
From same serie
We use cookies to enhance your experience.