Details
- Sensors
- Inductive proximity switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 60HZ
- - -V
Rated control supply voltage Us at AC 50HZ
- - -V
Height of sensor
18mm
Width sensor
-mm
Category according to EN 954-1
1
Type of switch function
Normally open contact
Type of switching output
NPN/NPN
Number of protected semiconductor outputs
1
Number of contact energized outputs with signalling function
0
Number of protected contact energized outputs
0
Type of interface
None
Number of semiconductor outputs with signalling function
1
Suitable for safety functions
No
Diameter sensor
18mm
Type of electric connection
Cable radial
Length of sensor
54.5mm
Compression-resistant
No
Explosion safety category for gas
None
Interference resistance to magnetic fields
Immune against magnetic DC-field
Coating housing
Other
Type of actuation
Metallic Target
Construction type housing
Cylinder plain
Switching distance
12mm
Supply voltage
12 - 24V
Max. output current at protected output
200mA
Explosion safety category for dust
None
Switching frequency
1000Hz
Type of interface for safety communication
None
Voltage type
AC/DC
Performance level according to EN ISO 13849-1
None
SIL according to IEC 61508
None
Rated control supply voltage Us at DC
12 - 24V
With monitoring function downstream switching devices
No
Material housing
Metal
Mechanical mounting condition for sensor
Not flat
Cascadable
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XS2L2SANAL2

Details
- Sensors
- Inductive proximity switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 60HZ
- .. -V
Rated control supply voltage Us at AC 50HZ
- .. -V
Height of sensor
18mm
Width sensor
-mm
Category according to EN 954-1
1
Type of switch function
Normally open contact
Type of switching output
NPN/NPN
Number of protected semiconductor outputs
1
Number of contact energized outputs with signalling function
0
Number of protected contact energized outputs
0
Type of interface
None
Number of semiconductor outputs with signalling function
1
Suitable for safety functions
Diameter sensor
18mm
Type of electric connection
Cable radial
Length of sensor
54.5mm
Compression-resistant
Explosion safety category for gas
None
Interference resistance to magnetic fields
Immune against magnetic DC-field
Coating housing
Other
Type of actuation
Metallic Target
Construction type housing
Cylinder plain
Switching distance
12mm
Supply voltage
12 .. 24V
Max. output current at protected output
200mA
Explosion safety category for dust
None
Switching frequency
1000Hz
Type of interface for safety communication
None
Voltage type
AC/DC
Performance level according to EN ISO 13849-1
None
SIL according to IEC 61508
None
Rated control supply voltage Us at DC
12 .. 24V
With monitoring function downstream switching devices
Material housing
Metal
Mechanical mounting condition for sensor
Not flat
Cascadable
From same serie
We use cookies to enhance your experience.