Details
- Sensors
- Inductive proximity switch
- 1 KOM
- SCHNEIDER
Technical specifications
Voltage type
AC/DC
Material housing
Metal
Rated control supply voltage Us at DC
12 - 24V
Type of electric connection
Connector M12
Explosion safety category for dust
None
Length of sensor
48mm
Explosion safety category for gas
None
Diameter sensor
12mm
Construction type housing
Cylinder, screw-thread
Type of interface
None
Coating housing
Nickel-plated
SIL according to IEC 61508
None
With monitoring function downstream switching devices
No
Switching frequency
5000Hz
Number of protected semiconductor outputs
2
Supply voltage
12 - 24V
Type of switching output
NPN/NPN
Category according to EN 954-1
1
Type of switch function
Other
Number of contact energized outputs with signalling function
0
Number of semiconductor outputs with signalling function
2
Max. output current at protected output
200mA
Type of interface for safety communication
None
Performance level according to EN ISO 13849-1
None
Number of protected contact energized outputs
0
Suitable for safety functions
No
Cascadable
No
Interference resistance to magnetic fields
Immune against magnetic DC-field
Switching distance
2mm
Mechanical mounting condition for sensor
Concise
Compression-resistant
No
Type of actuation
Metallic Target
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XS1N12NC410D

Details
- Sensors
- Inductive proximity switch
- 1 KOM
- SCHNEIDER
Technical specifications
Voltage type
AC/DC
Material housing
Metal
Rated control supply voltage Us at DC
12 .. 24V
Type of electric connection
Connector M12
Explosion safety category for dust
None
Length of sensor
48mm
Explosion safety category for gas
None
Diameter sensor
12mm
Construction type housing
Cylinder, screw-thread
Type of interface
None
Coating housing
Nickel-plated
SIL according to IEC 61508
None
With monitoring function downstream switching devices
Switching frequency
5000Hz
Number of protected semiconductor outputs
2
Supply voltage
12 .. 24V
Type of switching output
NPN/NPN
Category according to EN 954-1
1
Type of switch function
Other
Number of contact energized outputs with signalling function
0
Number of semiconductor outputs with signalling function
2
Max. output current at protected output
200mA
Type of interface for safety communication
None
Performance level according to EN ISO 13849-1
None
Number of protected contact energized outputs
0
Suitable for safety functions
Cascadable
Interference resistance to magnetic fields
Immune against magnetic DC-field
Switching distance
2mm
Mechanical mounting condition for sensor
Concise
Compression-resistant
Type of actuation
Metallic Target
From same serie