

Details
- Sensors
- Inductive proximity switch
- 1 KOM
- SCHNEIDER
Technical specifications
Category according to EN 954-1
1
Mechanical mounting condition for sensor
Concise
Type of switching output
2-wire
Number of contact energized outputs with signalling function
0
Suitable for safety functions
No
Number of semiconductor outputs with signalling function
0
Length of sensor
50mm
Coating housing
Nickel-plated
Construction type housing
Cylinder, screw-thread
Max. output current at protected output
1mA
Cascadable
No
Performance level according to EN ISO 13849-1
None
Material housing
Metal
Compression-resistant
No
Interference resistance to magnetic fields
Immune against magnetic DC-field
Explosion safety category for gas
None
Number of protected contact energized outputs
0
Diameter sensor
12mm
Type of electric connection
Cable radial
SIL according to IEC 61508
None
Number of protected semiconductor outputs
0
Supply voltage
12 - 24V
Type of interface for safety communication
None
Voltage type
AC/DC
Switching frequency
1500Hz
Explosion safety category for dust
Other
Rated control supply voltage Us at DC
12 - 24V
Switching distance
2mm
With monitoring function downstream switching devices
No
Type of interface
None
Type of switch function
Breaker contact
Type of actuation
Metallic Target
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XS1M12AB120EX

Details
- Sensors
- Inductive proximity switch
- 1 KOM
- SCHNEIDER
Technical specifications
Category according to EN 954-1
1
Mechanical mounting condition for sensor
Concise
Type of switching output
2-wire
Number of contact energized outputs with signalling function
0
Suitable for safety functions
Number of semiconductor outputs with signalling function
0
Length of sensor
50mm
Coating housing
Nickel-plated
Construction type housing
Cylinder, screw-thread
Max. output current at protected output
1mA
Cascadable
Performance level according to EN ISO 13849-1
None
Material housing
Metal
Compression-resistant
Interference resistance to magnetic fields
Immune against magnetic DC-field
Explosion safety category for gas
None
Number of protected contact energized outputs
0
Diameter sensor
12mm
Type of electric connection
Cable radial
SIL according to IEC 61508
None
Number of protected semiconductor outputs
0
Supply voltage
12 .. 24V
Type of interface for safety communication
None
Voltage type
AC/DC
Switching frequency
1500Hz
Explosion safety category for dust
Other
Rated control supply voltage Us at DC
12 .. 24V
Switching distance
2mm
With monitoring function downstream switching devices
Type of interface
None
Type of switch function
Breaker contact
Type of actuation
Metallic Target
From same serie
We use cookies to enhance your experience.