Details
- Sensors
- Inductive proximity switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Height of sensor
-mm
Width sensor
-mm
Category according to EN 954-1
1
Construction type housing
Cylinder plain
SIL according to IEC 61508
None
Material housing
Metal
Explosion safety category for dust
None
Diameter sensor
4mm
Performance level according to EN ISO 13849-1
None
Explosion safety category for gas
None
Number of semiconductor outputs with signalling function
1
Type of switch function
Breaker contact
Max. output current at protected output
100mA
Type of electric connection
Cable radial
Compression-resistant
No
Switching frequency
5000Hz
Coating housing
Nickel-plated
Number of protected contact energized outputs
0
Suitable for safety functions
No
Number of protected semiconductor outputs
1
Type of actuation
Metallic Target
Cascadable
No
Type of interface for safety communication
None
Length of sensor
29mm
Type of switching output
NPN/NPN
Number of contact energized outputs with signalling function
0
Rated control supply voltage Us at DC
12 - 24V
Mechanical mounting condition for sensor
Concise
Switching distance
1mm
Interference resistance to magnetic fields
Immune against magnetic DC-field
With monitoring function downstream switching devices
No
Supply voltage
5 - 24V
Voltage type
AC/DC
Type of interface
None
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XS1L04NB310

Details
- Sensors
- Inductive proximity switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Height of sensor
-mm
Width sensor
-mm
Category according to EN 954-1
1
Construction type housing
Cylinder plain
SIL according to IEC 61508
None
Material housing
Metal
Explosion safety category for dust
None
Diameter sensor
4mm
Performance level according to EN ISO 13849-1
None
Explosion safety category for gas
None
Number of semiconductor outputs with signalling function
1
Type of switch function
Breaker contact
Max. output current at protected output
100mA
Type of electric connection
Cable radial
Compression-resistant
Switching frequency
5000Hz
Coating housing
Nickel-plated
Number of protected contact energized outputs
0
Suitable for safety functions
Number of protected semiconductor outputs
1
Type of actuation
Metallic Target
Cascadable
Type of interface for safety communication
None
Length of sensor
29mm
Type of switching output
NPN/NPN
Number of contact energized outputs with signalling function
0
Rated control supply voltage Us at DC
12 .. 24V
Mechanical mounting condition for sensor
Concise
Switching distance
1mm
Interference resistance to magnetic fields
Immune against magnetic DC-field
With monitoring function downstream switching devices
Supply voltage
5 .. 24V
Voltage type
AC/DC
Type of interface
None
From same serie
We use cookies to enhance your experience.