Technical specifications
Rated operation power at AC-3, 400 V
-kW
Rated operation current Ie at AC-3, 400 V
-A
Rated operation current Ie at AC-1, 400 V
-A
Rated voltage Ue at DC
- - -V
Adjustable current range
- - -A
Max. operation pressure
12000hPa
Max. test pressure
-bar
Switching capacity at AC-3, 240 V
-kA
Max. operating pressure
12000hPa
Thread size
Other
Medium temperature
0 - 70°C
Explosion-proof
No
Degree of protection (NEMA)
Other
Suitable as 2-point controller
Yes
Suitable as guard
Yes
Engaging pressure
1.3 - 12bar
Rated voltage Ue at AC 60 Hz
230 - 400V
Initial setting
1300 - 12000hPa
Number of auxiliary contacts as normally open contact
0
End setting
300 - 10300hPa
Bursting pressure
30bar
Number of auxiliary contacts as change-over contact
0
Pressure-switching differential
8.4bar
Rated voltage Ue at AC 50 Hz
230 - 400V
Number of normally closed contacts as main contact
2
Switch off pressure
0.3 - 10.3bar
With hand operation
Yes
Number of auxiliary contacts as normally closed contact
0
Number of normally open contacts as main contact
0
With display
No
End value measuring range pressure
1200000Pa
Electronic version
No
Type of electric connection
Screw connection
With manual on/off switch
Yes
Degree of protection (IP)
IP54
Initial value measuring range pressure
130000Pa
Suitable as limiter
Yes
Height
125mm
Width
57mm
Depth
98mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XMPC12B2131
Details
- Low-voltage industrial components
- Pressure switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Rated operation current Ie at AC-3, 400 V
-A
Rated operation current Ie at AC-1, 400 V
-A
Rated voltage Ue at DC
- .. -V
Adjustable current range
- .. -A
Max. operation pressure
12000hPa
Max. test pressure
-bar
Switching capacity at AC-3, 240 V
-kA
Max. operating pressure
12000hPa
Thread size
Other
Medium temperature
0 .. 70°C
Explosion-proof
Degree of protection (NEMA)
Other
Suitable as 2-point controller
Suitable as guard
Engaging pressure
1.3 .. 12bar
Rated voltage Ue at AC 60 Hz
230 .. 400V
Initial setting
1300 .. 12000hPa
Number of auxiliary contacts as normally open contact
0
End setting
300 .. 10300hPa
Bursting pressure
30bar
Number of auxiliary contacts as change-over contact
0
Pressure-switching differential
8.4bar
Rated voltage Ue at AC 50 Hz
230 .. 400V
Number of normally closed contacts as main contact
2
Switch off pressure
0.3 .. 10.3bar
With hand operation
Number of auxiliary contacts as normally closed contact
0
Number of normally open contacts as main contact
0
With display
End value measuring range pressure
1200000Pa
Electronic version
Type of electric connection
Screw connection
With manual on/off switch
Degree of protection (IP)
IP54
Initial value measuring range pressure
130000Pa
Suitable as limiter
Height
125mm
Width
57mm
Depth
98mm
From same serie