Technical specifications
Rated operation power at AC-3, 400 V
-kW
Rated operation current Ie at AC-3, 400 V
-A
Rated operation current Ie at AC-1, 400 V
-A
Adjustable current range
- - -A
Max. operation pressure
30000hPa
Initial value measuring range pressure
-Pa
End value measuring range pressure
-Pa
Switching capacity at AC-3, 240 V
-kA
Suitable as guard
Yes
Initial setting
42 - 330hPa
Suitable as 2-point controller
Yes
Pressure-switching differential
7.3bar
Max. test pressure
37.5bar
Thread size
Other
Rated voltage Ue at AC 50 Hz
120 - 240V
Rated voltage Ue at DC
250 - 250V
Number of normally closed contacts as main contact
0
Number of auxiliary contacts as normally closed contact
0
Number of normally open contacts as main contact
0
With manual on/off switch
No
With display
No
With hand operation
No
Degree of protection (IP)
IP66
Switch off pressure
0.002 - 0.242bar
Explosion-proof
No
Depth
85mm
Height
113mm
Number of auxiliary contacts as change-over contact
2
Width
46mm
Electronic version
No
Degree of protection (NEMA)
Other
Max. operating pressure
330hPa
Type of electric connection
Screw connection
End setting
2 - 242hPa
Medium temperature
0 - 160°C
Bursting pressure
67.5bar
Rated voltage Ue at AC 60 Hz
120 - 240V
Suitable as limiter
Yes
Engaging pressure
0.042 - 0.33bar
Number of auxiliary contacts as normally open contact
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XMLCS35R2S11
Details
- Low-voltage industrial components
- Pressure switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Rated operation current Ie at AC-3, 400 V
-A
Rated operation current Ie at AC-1, 400 V
-A
Adjustable current range
- .. -A
Max. operation pressure
30000hPa
Initial value measuring range pressure
-Pa
End value measuring range pressure
-Pa
Switching capacity at AC-3, 240 V
-kA
Suitable as guard
Initial setting
42 .. 330hPa
Suitable as 2-point controller
Pressure-switching differential
7.3bar
Max. test pressure
37.5bar
Thread size
Other
Rated voltage Ue at AC 50 Hz
120 .. 240V
Rated voltage Ue at DC
250 .. 250V
Number of normally closed contacts as main contact
0
Number of auxiliary contacts as normally closed contact
0
Number of normally open contacts as main contact
0
With manual on/off switch
With display
With hand operation
Degree of protection (IP)
IP66
Switch off pressure
0.002 .. 0.242bar
Explosion-proof
Depth
85mm
Height
113mm
Number of auxiliary contacts as change-over contact
2
Width
46mm
Electronic version
Degree of protection (NEMA)
Other
Max. operating pressure
330hPa
Type of electric connection
Screw connection
End setting
2 .. 242hPa
Medium temperature
0 .. 160°C
Bursting pressure
67.5bar
Rated voltage Ue at AC 60 Hz
120 .. 240V
Suitable as limiter
Engaging pressure
0.042 .. 0.33bar
Number of auxiliary contacts as normally open contact
0