Details
- Low-voltage industrial components
- Pressure switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Rated operation current Ie at AC-3, 400 V
-A
Rated operation current Ie at AC-1, 400 V
-A
Adjustable current range
- - -A
Max. operation pressure
375000hPa
End value measuring range pressure
-Pa
Initial value measuring range pressure
-Pa
Switching capacity at AC-3, 240 V
-kA
Suitable as 2-point controller
Yes
Suitable as guard
Yes
Max. operating pressure
300000hPa
End setting
2600 - 263000hPa
Rated voltage Ue at DC
250 - 250V
Medium temperature
0 - 160°C
Number of auxiliary contacts as normally open contact
0
Pressure-switching differential
163bar
Number of normally open contacts as main contact
0
Number of normally closed contacts as main contact
0
Degree of protection (IP)
IP66
Depth
75mm
Initial setting
22000 - 300000hPa
Number of auxiliary contacts as change-over contact
1
Number of auxiliary contacts as normally closed contact
0
Rated voltage Ue at AC 60 Hz
120 - 240V
With manual on/off switch
No
Switch off pressure
2.6 - 263bar
Bursting pressure
135bar
Rated voltage Ue at AC 50 Hz
120 - 240V
Thread size
Other
Engaging pressure
22 - 300bar
With hand operation
No
With display
No
Suitable as limiter
No
Explosion-proof
No
Type of electric connection
Screw connection
Height
113mm
Max. test pressure
675bar
Degree of protection (NEMA)
Other
Electronic version
Yes
Width
35mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XMLB300D2S11

Details
- Low-voltage industrial components
- Pressure switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Rated operation current Ie at AC-3, 400 V
-A
Rated operation current Ie at AC-1, 400 V
-A
Adjustable current range
- .. -A
Max. operation pressure
375000hPa
End value measuring range pressure
-Pa
Initial value measuring range pressure
-Pa
Switching capacity at AC-3, 240 V
-kA
Suitable as 2-point controller
Suitable as guard
Max. operating pressure
300000hPa
End setting
2600 .. 263000hPa
Rated voltage Ue at DC
250 .. 250V
Medium temperature
0 .. 160°C
Number of auxiliary contacts as normally open contact
0
Pressure-switching differential
163bar
Number of normally open contacts as main contact
0
Number of normally closed contacts as main contact
0
Degree of protection (IP)
IP66
Depth
75mm
Initial setting
22000 .. 300000hPa
Number of auxiliary contacts as change-over contact
1
Number of auxiliary contacts as normally closed contact
0
Rated voltage Ue at AC 60 Hz
120 .. 240V
With manual on/off switch
Switch off pressure
2.6 .. 263bar
Bursting pressure
135bar
Rated voltage Ue at AC 50 Hz
120 .. 240V
Thread size
Other
Engaging pressure
22 .. 300bar
With hand operation
With display
Suitable as limiter
Explosion-proof
Type of electric connection
Screw connection
Height
113mm
Max. test pressure
675bar
Degree of protection (NEMA)
Other
Electronic version
Width
35mm
From same serie