Details
- Low-voltage industrial components
- Pressure switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Rated operation current Ie at AC-3, 400 V
-A
Rated operation current Ie at AC-1, 400 V
-A
Adjustable current range
- - -A
Max. operation pressure
200000hPa
End value measuring range pressure
-Pa
Initial value measuring range pressure
-Pa
Switching capacity at AC-3, 240 V
-kA
Suitable as 2-point controller
Yes
Suitable as limiter
Yes
Engaging pressure
10 - 160bar
Switch off pressure
0.7 - 139.2bar
Initial setting
10000 - 160000hPa
Max. test pressure
360bar
Number of auxiliary contacts as normally open contact
0
Max. operating pressure
160000hPa
Suitable as guard
Yes
Medium temperature
0 - 160°C
Bursting pressure
720bar
Thread size
Other
Rated voltage Ue at DC
250 - 250V
End setting
700 - 139200hPa
Number of normally open contacts as main contact
0
Number of auxiliary contacts as change-over contact
1
Number of normally closed contacts as main contact
0
Rated voltage Ue at AC 60 Hz
120 - 240V
Number of auxiliary contacts as normally closed contact
0
Rated voltage Ue at AC 50 Hz
120 - 240V
Electronic version
No
With display
No
With hand operation
No
Degree of protection (NEMA)
Other
Explosion-proof
No
Height
113mm
With manual on/off switch
No
Type of electric connection
Screw connection
Depth
75mm
Degree of protection (IP)
IP66
Pressure-switching differential
79.2bar
Width
35mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XMLB160D2S12

Details
- Low-voltage industrial components
- Pressure switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Rated operation current Ie at AC-3, 400 V
-A
Rated operation current Ie at AC-1, 400 V
-A
Adjustable current range
- .. -A
Max. operation pressure
200000hPa
End value measuring range pressure
-Pa
Initial value measuring range pressure
-Pa
Switching capacity at AC-3, 240 V
-kA
Suitable as 2-point controller
Suitable as limiter
Engaging pressure
10 .. 160bar
Switch off pressure
0.7 .. 139.2bar
Initial setting
10000 .. 160000hPa
Max. test pressure
360bar
Number of auxiliary contacts as normally open contact
0
Max. operating pressure
160000hPa
Suitable as guard
Medium temperature
0 .. 160°C
Bursting pressure
720bar
Thread size
Other
Rated voltage Ue at DC
250 .. 250V
End setting
700 .. 139200hPa
Number of normally open contacts as main contact
0
Number of auxiliary contacts as change-over contact
1
Number of normally closed contacts as main contact
0
Rated voltage Ue at AC 60 Hz
120 .. 240V
Number of auxiliary contacts as normally closed contact
0
Rated voltage Ue at AC 50 Hz
120 .. 240V
Electronic version
With display
With hand operation
Degree of protection (NEMA)
Other
Explosion-proof
Height
113mm
With manual on/off switch
Type of electric connection
Screw connection
Depth
75mm
Degree of protection (IP)
IP66
Pressure-switching differential
79.2bar
Width
35mm
From same serie