Details
- Low-voltage industrial components
- Pressure switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Rated operation current Ie at AC-3, 400 V
-A
Rated operation current Ie at AC-1, 400 V
-A
Adjustable current range
- - -A
Max. operation pressure
200000hPa
End value measuring range pressure
-Pa
Initial value measuring range pressure
-Pa
Switching capacity at AC-3, 240 V
-kA
Suitable as guard
Yes
Suitable as 2-point controller
Yes
Suitable as limiter
Yes
Engaging pressure
10 - 160bar
Pressure-switching differential
79.2bar
Medium temperature
0 - 160°C
End setting
700 - 139200hPa
Bursting pressure
720bar
Rated voltage Ue at AC 60 Hz
120 - 240V
Thread size
Other
Number of auxiliary contacts as change-over contact
1
Number of auxiliary contacts as normally open contact
0
Type of electric connection
Other
Max. operating pressure
160000hPa
Rated voltage Ue at DC
250 - 250V
Rated voltage Ue at AC 50 Hz
120 - 240V
Initial setting
10000 - 160000hPa
With hand operation
No
With manual on/off switch
No
Electronic version
No
Number of normally open contacts as main contact
0
Max. test pressure
360bar
Switch off pressure
0.7 - 139.2bar
Degree of protection (IP)
IP65/IP67
Number of auxiliary contacts as normally closed contact
0
Number of normally closed contacts as main contact
0
Explosion-proof
No
Height
113mm
Depth
75mm
Width
35mm
Degree of protection (NEMA)
Other
With display
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XMLB160D2C11

Details
- Low-voltage industrial components
- Pressure switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Rated operation current Ie at AC-3, 400 V
-A
Rated operation current Ie at AC-1, 400 V
-A
Adjustable current range
- .. -A
Max. operation pressure
200000hPa
End value measuring range pressure
-Pa
Initial value measuring range pressure
-Pa
Switching capacity at AC-3, 240 V
-kA
Suitable as guard
Suitable as 2-point controller
Suitable as limiter
Engaging pressure
10 .. 160bar
Pressure-switching differential
79.2bar
Medium temperature
0 .. 160°C
End setting
700 .. 139200hPa
Bursting pressure
720bar
Rated voltage Ue at AC 60 Hz
120 .. 240V
Thread size
Other
Number of auxiliary contacts as change-over contact
1
Number of auxiliary contacts as normally open contact
0
Type of electric connection
Other
Max. operating pressure
160000hPa
Rated voltage Ue at DC
250 .. 250V
Rated voltage Ue at AC 50 Hz
120 .. 240V
Initial setting
10000 .. 160000hPa
With hand operation
With manual on/off switch
Electronic version
Number of normally open contacts as main contact
0
Max. test pressure
360bar
Switch off pressure
0.7 .. 139.2bar
Degree of protection (IP)
IP65/IP67
Number of auxiliary contacts as normally closed contact
0
Number of normally closed contacts as main contact
0
Explosion-proof
Height
113mm
Depth
75mm
Width
35mm
Degree of protection (NEMA)
Other
With display