Details
- Low-voltage industrial components
- Pressure switch
- 1 KOM
- SCHNEIDER
Technical specifications
Degree of protection (IP)
IP65/IP67
Width
35mm
Height
113mm
Depth
75mm
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
1
Degree of protection (NEMA)
Other
Type of electric connection
Other
Number of normally closed contacts as main contact
0
Number of normally open contacts as main contact
0
Explosion-proof
No
With display
No
Rated voltage Ue at AC 50 Hz
120 - 240V
Rated voltage Ue at AC 60 Hz
120 - 240V
Rated voltage Ue at DC
250 - 250V
Max. operation pressure
12500hPa
Electronic version
No
Suitable as limiter
Yes
With manual on/off switch
No
Bursting pressure
45bar
Suitable as 2-point controller
Yes
Medium temperature
0 - 160°C
Pressure-switching differential
0.57bar
With hand operation
No
Suitable as guard
Yes
End setting
130 - 9150hPa
Engaging pressure
0.7 - 10bar
Switch off pressure
0.13 - 9.15bar
Initial setting
700 - 10000hPa
Max. test pressure
22.5bar
Thread size
Other
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XMLB010C2C11
Details
- Low-voltage industrial components
- Pressure switch
- 1 KOM
- SCHNEIDER
Technical specifications
Degree of protection (IP)
IP65/IP67
Width
35mm
Height
113mm
Depth
75mm
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
1
Degree of protection (NEMA)
Other
Type of electric connection
Other
Number of normally closed contacts as main contact
0
Number of normally open contacts as main contact
0
Explosion-proof
With display
Rated voltage Ue at AC 50 Hz
120 .. 240V
Rated voltage Ue at AC 60 Hz
120 .. 240V
Rated voltage Ue at DC
250 .. 250V
Max. operation pressure
12500hPa
Electronic version
Suitable as limiter
With manual on/off switch
Bursting pressure
45bar
Suitable as 2-point controller
Medium temperature
0 .. 160°C
Pressure-switching differential
0.57bar
With hand operation
Suitable as guard
End setting
130 .. 9150hPa
Engaging pressure
0.7 .. 10bar
Switch off pressure
0.13 .. 9.15bar
Initial setting
700 .. 10000hPa
Max. test pressure
22.5bar
Thread size
Other
From same serie