

Details
- Low-voltage industrial components
- Pressure switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Rated operation current Ie at AC-3, 400 V
-A
Rated operation current Ie at AC-1, 400 V
-A
Adjustable current range
- - -A
Max. operation pressure
12500hPa
End value measuring range pressure
-Pa
Initial value measuring range pressure
-Pa
Switching capacity at AC-3, 240 V
-kA
Max. operating pressure
10000hPa
Engaging pressure
0.7 - 10bar
Suitable as guard
Yes
Initial setting
700 - 10000hPa
Pressure-switching differential
6.65bar
Suitable as 2-point controller
Yes
Rated voltage Ue at AC 50 Hz
120 - 240V
Bursting pressure
45bar
Medium temperature
0 - 70°C
Max. test pressure
22.5bar
Thread size
Other
Suitable as limiter
Yes
Number of auxiliary contacts as normally closed contact
0
Electronic version
No
Number of normally open contacts as main contact
0
Type of electric connection
Other
With manual on/off switch
No
Explosion-proof
No
Degree of protection (NEMA)
Other
With display
No
Depth
75mm
Number of normally closed contacts as main contact
0
Degree of protection (IP)
IP65/IP67
Height
113mm
Width
35mm
With hand operation
No
Switch off pressure
0.13 - 9.15bar
Rated voltage Ue at AC 60 Hz
120 - 240V
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
1
End setting
130 - 9150hPa
Rated voltage Ue at DC
250 - 250V
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
Code: 1719715
XMLB010A2C11

Details
- Low-voltage industrial components
- Pressure switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Rated operation current Ie at AC-3, 400 V
-A
Rated operation current Ie at AC-1, 400 V
-A
Adjustable current range
- .. -A
Max. operation pressure
12500hPa
End value measuring range pressure
-Pa
Initial value measuring range pressure
-Pa
Switching capacity at AC-3, 240 V
-kA
Max. operating pressure
10000hPa
Engaging pressure
0.7 .. 10bar
Suitable as guard
Initial setting
700 .. 10000hPa
Pressure-switching differential
6.65bar
Suitable as 2-point controller
Rated voltage Ue at AC 50 Hz
120 .. 240V
Bursting pressure
45bar
Medium temperature
0 .. 70°C
Max. test pressure
22.5bar
Thread size
Other
Suitable as limiter
Number of auxiliary contacts as normally closed contact
0
Electronic version
Number of normally open contacts as main contact
0
Type of electric connection
Other
With manual on/off switch
Explosion-proof
Degree of protection (NEMA)
Other
With display
Depth
75mm
Number of normally closed contacts as main contact
0
Degree of protection (IP)
IP65/IP67
Height
113mm
Width
35mm
With hand operation
Switch off pressure
0.13 .. 9.15bar
Rated voltage Ue at AC 60 Hz
120 .. 240V
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
1
End setting
130 .. 9150hPa
Rated voltage Ue at DC
250 .. 250V
From same serie
We use cookies to enhance your experience.