Details
- Low-voltage industrial components
- Pressure switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Rated operation current Ie at AC-3, 400 V
-A
Rated operation current Ie at AC-1, 400 V
-A
Adjustable current range
- - -A
Max. operation pressure
1250hPa
End value measuring range pressure
-Pa
Initial value measuring range pressure
-Pa
Switching capacity at AC-3, 240 V
-kA
Engaging pressure
0.05 - 1bar
Suitable as 2-point controller
Yes
Switch off pressure
0.01 - 0.94bar
Max. test pressure
2.25bar
End setting
10 - 940hPa
Suitable as limiter
Yes
Rated voltage Ue at AC 60 Hz
120 - 240V
Thread size
Other
Pressure-switching differential
0.69bar
Number of auxiliary contacts as normally open contact
0
With hand operation
No
Bursting pressure
4.5bar
Electronic version
No
Number of normally open contacts as main contact
0
Rated voltage Ue at DC
250 - 250V
Medium temperature
0 - 160°C
Explosion-proof
No
Degree of protection (NEMA)
Other
With display
No
Number of normally closed contacts as main contact
0
Suitable as guard
Yes
Max. operating pressure
1000hPa
Rated voltage Ue at AC 50 Hz
120 - 240V
Initial setting
50 - 1000hPa
Number of auxiliary contacts as normally closed contact
0
Depth
110mm
Degree of protection (IP)
IP66
Type of electric connection
Screw connection
Width
110mm
With manual on/off switch
No
Number of auxiliary contacts as change-over contact
1
Height
162mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XMLB001S2S12

Details
- Low-voltage industrial components
- Pressure switch
- 1 KOM
- SCHNEIDER
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Rated operation current Ie at AC-3, 400 V
-A
Rated operation current Ie at AC-1, 400 V
-A
Adjustable current range
- .. -A
Max. operation pressure
1250hPa
End value measuring range pressure
-Pa
Initial value measuring range pressure
-Pa
Switching capacity at AC-3, 240 V
-kA
Engaging pressure
0.05 .. 1bar
Suitable as 2-point controller
Switch off pressure
0.01 .. 0.94bar
Max. test pressure
2.25bar
End setting
10 .. 940hPa
Suitable as limiter
Rated voltage Ue at AC 60 Hz
120 .. 240V
Thread size
Other
Pressure-switching differential
0.69bar
Number of auxiliary contacts as normally open contact
0
With hand operation
Bursting pressure
4.5bar
Electronic version
Number of normally open contacts as main contact
0
Rated voltage Ue at DC
250 .. 250V
Medium temperature
0 .. 160°C
Explosion-proof
Degree of protection (NEMA)
Other
With display
Number of normally closed contacts as main contact
0
Suitable as guard
Max. operating pressure
1000hPa
Rated voltage Ue at AC 50 Hz
120 .. 240V
Initial setting
50 .. 1000hPa
Number of auxiliary contacts as normally closed contact
0
Depth
110mm
Degree of protection (IP)
IP66
Type of electric connection
Screw connection
Width
110mm
With manual on/off switch
Number of auxiliary contacts as change-over contact
1
Height
162mm
From same serie