Details
- Low-voltage industrial components
- Pressure switch
- 1 KOM
- SCHNEIDER
Technical specifications
Max. operation pressure
5000hPa
Suitable as guard
Yes
Suitable as limiter
Yes
Suitable as 2-point controller
No
Max. operating pressure
-40hPa
Initial setting
-760 - -40hPa
Switch off pressure
-1 - -0.28bar
Bursting pressure
18bar
Medium temperature
0 - 70°C
Max. test pressure
9bar
Rated voltage Ue at DC
250 - 250V
Rated operation power at AC-3, 400 V
0kW
Number of auxiliary contacts as normally closed contact
0
Rated operation current Ie at AC-3, 400 V
0A
Switching capacity at AC-3, 240 V
0kA
Number of normally closed contacts as main contact
0
Number of auxiliary contacts as change-over contact
1
Number of auxiliary contacts as normally open contact
0
Engaging pressure
-0.76 - -0.04bar
End value measuring range pressure
0Pa
Pressure-switching differential
0.24bar
Initial value measuring range pressure
0Pa
Rated voltage Ue at AC 60 Hz
120 - 240V
Thread size
1/4 inch
Connection
Internal thread cylindrical BSPP-G (ISO 228-1)
Rated voltage Ue at AC 50 Hz
120 - 240V
End setting
-1000 - -280hPa
Rated operation current Ie at AC-1, 400 V
0A
Electronic version
No
With manual on/off switch
No
Number of normally open contacts as main contact
0
With hand operation
No
Explosion-proof
No
Degree of protection (NEMA)
Other
Adjustable current range
0 - 0A
Depth
75mm
Width
35mm
Type of electric connection
Screw connection
Degree of protection (IP)
IP66
Height
113mm
With display
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XMLAM01V2S12
Details
- Low-voltage industrial components
- Pressure switch
- 1 KOM
- SCHNEIDER
Technical specifications
Max. operation pressure
5000hPa
Suitable as guard
Suitable as limiter
Suitable as 2-point controller
Max. operating pressure
-40hPa
Initial setting
-760 .. -40hPa
Switch off pressure
-1 .. -0.28bar
Bursting pressure
18bar
Medium temperature
0 .. 70°C
Max. test pressure
9bar
Rated voltage Ue at DC
250 .. 250V
Rated operation power at AC-3, 400 V
0kW
Number of auxiliary contacts as normally closed contact
0
Rated operation current Ie at AC-3, 400 V
0A
Switching capacity at AC-3, 240 V
0kA
Number of normally closed contacts as main contact
0
Number of auxiliary contacts as change-over contact
1
Number of auxiliary contacts as normally open contact
0
Engaging pressure
-0.76 .. -0.04bar
End value measuring range pressure
0Pa
Pressure-switching differential
0.24bar
Initial value measuring range pressure
0Pa
Rated voltage Ue at AC 60 Hz
120 .. 240V
Thread size
1/4 inch
Connection
Internal thread cylindrical BSPP-G (ISO 228-1)
Rated voltage Ue at AC 50 Hz
120 .. 240V
End setting
-1000 .. -280hPa
Rated operation current Ie at AC-1, 400 V
0A
Electronic version
With manual on/off switch
Number of normally open contacts as main contact
0
With hand operation
Explosion-proof
Degree of protection (NEMA)
Other
Adjustable current range
0 .. 0A
Depth
75mm
Width
35mm
Type of electric connection
Screw connection
Degree of protection (IP)
IP66
Height
113mm
With display
From same serie