Details
- Low-voltage industrial components
- Pressure switch
- 1 KOM
- SCHNEIDER
Technical specifications
Adjustable current range
0 - 0A
Max. operation pressure
5000hPa
Suitable as limiter
No
Suitable as guard
Yes
Suitable as 2-point controller
No
Engaging pressure
0.15 - 2.5bar
Max. operating pressure
2500hPa
Initial setting
150 - 2500hPa
Pressure-switching differential
0.13bar
Medium temperature
0 - 160°C
Rated voltage Ue at AC 50 Hz
120 - 240V
Max. test pressure
9bar
Connection
Internal thread cylindrical BSPP-G (ISO 228-1)
Bursting pressure
18bar
Switch off pressure
0.02 - 2.37bar
End setting
20 - 2370hPa
Number of normally closed contacts as main contact
0
Switching capacity at AC-3, 240 V
0kA
Number of normally open contacts as main contact
0
Rated operation current Ie at AC-1, 400 V
0A
Number of auxiliary contacts as change-over contact
1
Rated voltage Ue at AC 60 Hz
120 - 240V
Degree of protection (NEMA)
Other
End value measuring range pressure
0Pa
Type of electric connection
Screw connection
Rated voltage Ue at DC
250 - 250V
With display
No
Thread size
1/4 inch
Initial value measuring range pressure
0Pa
With hand operation
No
Rated operation power at AC-3, 400 V
0kW
Rated operation current Ie at AC-3, 400 V
0A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Height
158mm
Depth
77.5mm
Degree of protection (IP)
IP66
Width
35mm
With manual on/off switch
No
Explosion-proof
No
Electronic version
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XMLA002B2S11

Details
- Low-voltage industrial components
- Pressure switch
- 1 KOM
- SCHNEIDER
Technical specifications
Adjustable current range
0 .. 0A
Max. operation pressure
5000hPa
Suitable as limiter
Suitable as guard
Suitable as 2-point controller
Engaging pressure
0.15 .. 2.5bar
Max. operating pressure
2500hPa
Initial setting
150 .. 2500hPa
Pressure-switching differential
0.13bar
Medium temperature
0 .. 160°C
Rated voltage Ue at AC 50 Hz
120 .. 240V
Max. test pressure
9bar
Connection
Internal thread cylindrical BSPP-G (ISO 228-1)
Bursting pressure
18bar
Switch off pressure
0.02 .. 2.37bar
End setting
20 .. 2370hPa
Number of normally closed contacts as main contact
0
Switching capacity at AC-3, 240 V
0kA
Number of normally open contacts as main contact
0
Rated operation current Ie at AC-1, 400 V
0A
Number of auxiliary contacts as change-over contact
1
Rated voltage Ue at AC 60 Hz
120 .. 240V
Degree of protection (NEMA)
Other
End value measuring range pressure
0Pa
Type of electric connection
Screw connection
Rated voltage Ue at DC
250 .. 250V
With display
Thread size
1/4 inch
Initial value measuring range pressure
0Pa
With hand operation
Rated operation power at AC-3, 400 V
0kW
Rated operation current Ie at AC-3, 400 V
0A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Height
158mm
Depth
77.5mm
Degree of protection (IP)
IP66
Width
35mm
With manual on/off switch
Explosion-proof
Electronic version
From same serie
We use cookies to enhance your experience.