![Main Product Image](https://assets.aleta.hr/415x415/b2299897-37d8-4aed-ba6f-4334f3318c91.webp)
![Main Product Image](https://assets.aleta.hr/415x415/b2299897-37d8-4aed-ba6f-4334f3318c91.webp)
Details
- Low-voltage industrial components
- Pressure switch
- 1 KOM
- SCHNEIDER
Technical specifications
Adjustable current range
0 - 0A
Max. operation pressure
1250hPa
Suitable as guard
Yes
End value measuring range pressure
0Pa
Rated operation power at AC-3, 400 V
0kW
Initial value measuring range pressure
0Pa
Thread size
1/4 inch
Number of normally closed contacts as main contact
0
Type of electric connection
Screw connection
Engaging pressure
0.03 - 1bar
Initial setting
30 - 1000hPa
Max. operating pressure
1000hPa
Max. test pressure
2.25bar
Pressure-switching differential
0.04bar
Bursting pressure
4.5bar
Switching capacity at AC-3, 240 V
0kA
Rated voltage Ue at AC 60 Hz
120 - 240V
Medium temperature
0 - 160°C
Connection
Internal thread cylindrical BSPP-G (ISO 228-1)
Suitable as limiter
Yes
Switch off pressure
0.01 - 0.96bar
Rated voltage Ue at AC 50 Hz
120 - 240V
Rated voltage Ue at DC
250 - 250V
Suitable as 2-point controller
No
Rated operation current Ie at AC-1, 400 V
0A
Number of auxiliary contacts as normally closed contact
0
Width
110mm
Degree of protection (NEMA)
Other
Number of auxiliary contacts as change-over contact
1
Number of normally open contacts as main contact
0
Rated operation current Ie at AC-3, 400 V
0A
With display
No
Electronic version
No
With hand operation
No
Height
162mm
Explosion-proof
No
With manual on/off switch
No
Degree of protection (IP)
IP66
Depth
110mm
Number of auxiliary contacts as normally open contact
0
End setting
10 - 960hPa
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XMLA001S2S11
![Main Product Image](https://assets.aleta.hr/300x300/0eafedf7-9f72-42d3-a032-daa1aa250997_optimized.webp)
Details
- Low-voltage industrial components
- Pressure switch
- 1 KOM
- SCHNEIDER
Technical specifications
Adjustable current range
0 .. 0A
Max. operation pressure
1250hPa
Suitable as guard
End value measuring range pressure
0Pa
Rated operation power at AC-3, 400 V
0kW
Initial value measuring range pressure
0Pa
Thread size
1/4 inch
Number of normally closed contacts as main contact
0
Type of electric connection
Screw connection
Engaging pressure
0.03 .. 1bar
Initial setting
30 .. 1000hPa
Max. operating pressure
1000hPa
Max. test pressure
2.25bar
Pressure-switching differential
0.04bar
Bursting pressure
4.5bar
Switching capacity at AC-3, 240 V
0kA
Rated voltage Ue at AC 60 Hz
120 .. 240V
Medium temperature
0 .. 160°C
Connection
Internal thread cylindrical BSPP-G (ISO 228-1)
Suitable as limiter
Switch off pressure
0.01 .. 0.96bar
Rated voltage Ue at AC 50 Hz
120 .. 240V
Rated voltage Ue at DC
250 .. 250V
Suitable as 2-point controller
Rated operation current Ie at AC-1, 400 V
0A
Number of auxiliary contacts as normally closed contact
0
Width
110mm
Degree of protection (NEMA)
Other
Number of auxiliary contacts as change-over contact
1
Number of normally open contacts as main contact
0
Rated operation current Ie at AC-3, 400 V
0A
With display
Electronic version
With hand operation
Height
162mm
Explosion-proof
With manual on/off switch
Degree of protection (IP)
IP66
Depth
110mm
Number of auxiliary contacts as normally open contact
0
End setting
10 .. 960hPa
From same serie