Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
Other
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 125 V
6A
Length of sensor
30mm
Rated operation current Ie at AC-15, 230 V
3A
Rated operation current Ie at DC-13, 230 V
0.27A
Height of sensor
161mm
Switching function latching
No
Forced opening
No
Rated operation current Ie at DC-13, 125 V
0.55A
Width sensor
30mm
Material housing
Plastic
Alignment of the control element
Other
Explosion safety category for dust
None
Type of control element
Rotary lever
Suitable for safety functions
Yes
Type of interface for safety communication
None
Coating housing
Other
Degree of protection (IP)
IP67K
With status indication
No
Switching function
Slow-action switch and quick-break switch
Explosion safety category for gas
None
Ambient temperature during operating
-25 - 70°C
Output electronic
No
Construction type housing
Cuboid
Number of contacts as change-over contact
0
Number of safety auxiliary contacts
0
Number of contacts as normally closed contact
2
Type of electric connection
Cable entry metrical
Type of interface
None
Number of contacts as normally open contact
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XCSPL752

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
Other
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 125 V
6A
Length of sensor
30mm
Rated operation current Ie at AC-15, 230 V
3A
Rated operation current Ie at DC-13, 230 V
0.27A
Height of sensor
161mm
Switching function latching
Forced opening
Rated operation current Ie at DC-13, 125 V
0.55A
Width sensor
30mm
Material housing
Plastic
Alignment of the control element
Other
Explosion safety category for dust
None
Type of control element
Rotary lever
Suitable for safety functions
Type of interface for safety communication
None
Coating housing
Other
Degree of protection (IP)
IP67K
With status indication
Switching function
Slow-action switch and quick-break switch
Explosion safety category for gas
None
Ambient temperature during operating
-25 .. 70°C
Output electronic
Construction type housing
Cuboid
Number of contacts as change-over contact
0
Number of safety auxiliary contacts
0
Number of contacts as normally closed contact
2
Type of electric connection
Cable entry metrical
Type of interface
None
Number of contacts as normally open contact
0
From same serie