Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at AC-15, 125 V
0A
Housing according to norm
Other
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Number of safety auxiliary contacts
0
Construction type housing
Cuboid
Number of contacts as change-over contact
0
Width sensor
34mm
Length of sensor
35mm
Height of sensor
122mm
Forced opening
No
Switching function latching
No
Output electronic
No
Switching function
Quick-break switch
Type of electric connection
Cable entry metrical
Material housing
Metal
Number of contacts as normally closed contact
2
Type of control element
Roller lever
Type of interface
None
Rated operation current Ie at DC-13, 230 V
0.1A
Rated operation current Ie at AC-15, 230 V
1.5A
Degree of protection (IP)
IP67K
Ambient temperature during operating
-25 - 70°C
Type of interface for safety communication
None
Alignment of the control element
Other
With status indication
No
Coating housing
Other
Explosion safety category for dust
None
Suitable for safety functions
Yes
Explosion safety category for gas
None
Number of contacts as normally open contact
1
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XCSD3918P20

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at AC-15, 125 V
0A
Housing according to norm
Other
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Number of safety auxiliary contacts
0
Construction type housing
Cuboid
Number of contacts as change-over contact
0
Width sensor
34mm
Length of sensor
35mm
Height of sensor
122mm
Forced opening
Switching function latching
Output electronic
Switching function
Quick-break switch
Type of electric connection
Cable entry metrical
Material housing
Metal
Number of contacts as normally closed contact
2
Type of control element
Roller lever
Type of interface
None
Rated operation current Ie at DC-13, 230 V
0.1A
Rated operation current Ie at AC-15, 230 V
1.5A
Degree of protection (IP)
IP67K
Ambient temperature during operating
-25 .. 70°C
Type of interface for safety communication
None
Alignment of the control element
Other
With status indication
Coating housing
Other
Explosion safety category for dust
None
Suitable for safety functions
Explosion safety category for gas
None
Number of contacts as normally open contact
1