Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at AC-15, 125 V
0A
Housing according to norm
Other
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Width sensor
34mm
Rated operation current Ie at DC-13, 230 V
0.1A
Rated operation current Ie at AC-15, 230 V
1.5A
Output electronic
No
Forced opening
No
Length of sensor
35mm
Construction type housing
Cuboid
Type of electric connection
Cable entry PG
Switching function
Quick-break switch
Coating housing
Other
Number of contacts as normally closed contact
2
Type of interface
None
Type of control element
Plunger
Number of contacts as normally open contact
1
Type of interface for safety communication
None
Suitable for safety functions
Yes
With status indication
No
Ambient temperature during operating
-25 - 70°C
Explosion safety category for dust
None
Degree of protection (IP)
IP67K
Switching function latching
No
Height of sensor
100mm
Number of contacts as change-over contact
0
Material housing
Metal
Explosion safety category for gas
None
Alignment of the control element
Other
Number of safety auxiliary contacts
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XCSD3902G13

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at AC-15, 125 V
0A
Housing according to norm
Other
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Width sensor
34mm
Rated operation current Ie at DC-13, 230 V
0.1A
Rated operation current Ie at AC-15, 230 V
1.5A
Output electronic
Forced opening
Length of sensor
35mm
Construction type housing
Cuboid
Type of electric connection
Cable entry PG
Switching function
Quick-break switch
Coating housing
Other
Number of contacts as normally closed contact
2
Type of interface
None
Type of control element
Plunger
Number of contacts as normally open contact
1
Type of interface for safety communication
None
Suitable for safety functions
With status indication
Ambient temperature during operating
-25 .. 70°C
Explosion safety category for dust
None
Degree of protection (IP)
IP67K
Switching function latching
Height of sensor
100mm
Number of contacts as change-over contact
0
Material housing
Metal
Explosion safety category for gas
None
Alignment of the control element
Other
Number of safety auxiliary contacts
0
From same serie