Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
Other
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Height of sensor
95mm
Forced opening
Yes
Output electronic
No
Rated operation current Ie at DC-13, 230 V
0.27A
Number of contacts as change-over contact
0
Type of interface
None
Construction type housing
Special construction
Material housing
Plastic
Number of contacts as normally open contact
2
Coating housing
Other
Type of control element
Adjustable roller lever
Number of contacts as normally closed contact
2
Type of interface for safety communication
None
Explosion safety category for dust
None
Number of safety auxiliary contacts
0
With status indication
No
Suitable for safety functions
No
Degree of protection (IP)
IP54
Rated operation current Ie at AC-15, 230 V
3A
Ambient temperature during operating
-25 - 70°C
Switching function latching
No
Switching function
Quick-break switch
Length of sensor
75mm
Explosion safety category for gas
None
Width sensor
85mm
Alignment of the control element
Other
Type of electric connection
Cable entry PG
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XCRB15

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
Other
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Height of sensor
95mm
Forced opening
Output electronic
Rated operation current Ie at DC-13, 230 V
0.27A
Number of contacts as change-over contact
0
Type of interface
None
Construction type housing
Special construction
Material housing
Plastic
Number of contacts as normally open contact
2
Coating housing
Other
Type of control element
Adjustable roller lever
Number of contacts as normally closed contact
2
Type of interface for safety communication
None
Explosion safety category for dust
None
Number of safety auxiliary contacts
0
With status indication
Suitable for safety functions
Degree of protection (IP)
IP54
Rated operation current Ie at AC-15, 230 V
3A
Ambient temperature during operating
-25 .. 70°C
Switching function latching
Switching function
Quick-break switch
Length of sensor
75mm
Explosion safety category for gas
None
Width sensor
85mm
Alignment of the control element
Other
Type of electric connection
Cable entry PG
From same serie