Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
Other
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at DC-13, 230 V
0.27A
Construction type housing
Cuboid
Rated operation current Ie at AC-15, 230 V
3A
Number of contacts as change-over contact
0
Forced opening
Yes
Width sensor
31mm
Type of interface for safety communication
None
Output electronic
No
Number of safety auxiliary contacts
0
Material housing
Plastic
Switching function
Quick-break switch
Length of sensor
30mm
Switching function latching
No
Degree of protection (IP)
IP67K
Coating housing
Other
Explosion safety category for gas
None
Number of contacts as normally closed contact
1
Type of electric connection
Cable entry PG
With status indication
No
Type of interface
None
Alignment of the control element
Other
Type of control element
Plunger
Number of contacts as normally open contact
1
Height of sensor
65mm
Suitable for safety functions
No
Ambient temperature during operating
-25 - 70°C
Explosion safety category for dust
None
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XCPR2110G13

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
Other
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at DC-13, 230 V
0.27A
Construction type housing
Cuboid
Rated operation current Ie at AC-15, 230 V
3A
Number of contacts as change-over contact
0
Forced opening
Width sensor
31mm
Type of interface for safety communication
None
Output electronic
Number of safety auxiliary contacts
0
Material housing
Plastic
Switching function
Quick-break switch
Length of sensor
30mm
Switching function latching
Degree of protection (IP)
IP67K
Coating housing
Other
Explosion safety category for gas
None
Number of contacts as normally closed contact
1
Type of electric connection
Cable entry PG
With status indication
Type of interface
None
Alignment of the control element
Other
Type of control element
Plunger
Number of contacts as normally open contact
1
Height of sensor
65mm
Suitable for safety functions
Ambient temperature during operating
-25 .. 70°C
Explosion safety category for dust
None
From same serie