Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
Other
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Width sensor
30mm
Length of sensor
16mm
Forced opening
Yes
Number of safety auxiliary contacts
1
Number of contacts as normally closed contact
1
Number of contacts as normally open contact
1
Height of sensor
50mm
Construction type housing
Other
Type of control element
Roller cam
Type of interface
None
Type of electric connection
With cable preassembled
Rated operation current Ie at DC-13, 230 V
0.1A
Explosion safety category for gas
None
Output electronic
No
Number of contacts as change-over contact
0
Material housing
Metal
Rated operation current Ie at AC-15, 230 V
1.5A
With status indication
No
Degree of protection (IP)
IP66/IP67
Alignment of the control element
Roller cam straight
Ambient temperature during operating
-25 - 70°C
Type of interface for safety communication
None
Explosion safety category for dust
None
Switching function
Quick-break switch
Switching function latching
No
Coating housing
Other
Suitable for safety functions
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XCMD21F2L1

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
Other
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Width sensor
30mm
Length of sensor
16mm
Forced opening
Number of safety auxiliary contacts
1
Number of contacts as normally closed contact
1
Number of contacts as normally open contact
1
Height of sensor
50mm
Construction type housing
Other
Type of control element
Roller cam
Type of interface
None
Type of electric connection
With cable preassembled
Rated operation current Ie at DC-13, 230 V
0.1A
Explosion safety category for gas
None
Output electronic
Number of contacts as change-over contact
0
Material housing
Metal
Rated operation current Ie at AC-15, 230 V
1.5A
With status indication
Degree of protection (IP)
IP66/IP67
Alignment of the control element
Roller cam straight
Ambient temperature during operating
-25 .. 70°C
Type of interface for safety communication
None
Explosion safety category for dust
None
Switching function
Quick-break switch
Switching function latching
Coating housing
Other
Suitable for safety functions
From same serie