Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
Other
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Length of sensor
16mm
Number of safety auxiliary contacts
0
Width sensor
30mm
Rated operation current Ie at AC-15, 230 V
1.5A
Rated operation current Ie at DC-13, 230 V
0.1A
Switching function
Quick-break switch
Number of contacts as normally closed contact
0
Number of contacts as normally open contact
0
Coating housing
Other
Type of interface
None
Switching function latching
No
Construction type housing
Cuboid
Alignment of the control element
Other
Forced opening
No
Type of interface for safety communication
None
Material housing
Metal
Ambient temperature during operating
-25 - 70°C
Number of contacts as change-over contact
1
With status indication
No
Type of electric connection
Connector M12
Explosion safety category for dust
None
Suitable for safety functions
No
Output electronic
No
Height of sensor
50mm
Type of control element
Spring-rod
Explosion safety category for gas
None
Degree of protection (IP)
IP67K
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XCMD2106M12

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
Other
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Length of sensor
16mm
Number of safety auxiliary contacts
0
Width sensor
30mm
Rated operation current Ie at AC-15, 230 V
1.5A
Rated operation current Ie at DC-13, 230 V
0.1A
Switching function
Quick-break switch
Number of contacts as normally closed contact
0
Number of contacts as normally open contact
0
Coating housing
Other
Type of interface
None
Switching function latching
Construction type housing
Cuboid
Alignment of the control element
Other
Forced opening
Type of interface for safety communication
None
Material housing
Metal
Ambient temperature during operating
-25 .. 70°C
Number of contacts as change-over contact
1
With status indication
Type of electric connection
Connector M12
Explosion safety category for dust
None
Suitable for safety functions
Output electronic
Height of sensor
50mm
Type of control element
Spring-rod
Explosion safety category for gas
None
Degree of protection (IP)
IP67K
From same serie
We use cookies to enhance your experience.