Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50047
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Width sensor
58mm
Length of sensor
30mm
Rated operation current Ie at AC-15, 230 V
3A
Height of sensor
51mm
Switching function latching
No
Number of contacts as normally open contact
1
Type of interface
None
Number of contacts as change-over contact
0
Number of contacts as normally closed contact
1
Forced opening
Yes
Number of safety auxiliary contacts
0
Alignment of the control element
Roller cam straight
Output electronic
No
Type of interface for safety communication
None
With status indication
No
Rated operation current Ie at DC-13, 230 V
0.27A
Type of control element
Roller cam
Type of electric connection
Cable entry PG
Explosion safety category for dust
None
Explosion safety category for gas
None
Coating housing
Other
Switching function
Quick-break switch
Material housing
Plastic
Suitable for safety functions
No
Degree of protection (IP)
IP66/IP67
Construction type housing
Special construction
Ambient temperature during operating
-25 - 70°C
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XCKT2121G11

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50047
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Width sensor
58mm
Length of sensor
30mm
Rated operation current Ie at AC-15, 230 V
3A
Height of sensor
51mm
Switching function latching
Number of contacts as normally open contact
1
Type of interface
None
Number of contacts as change-over contact
0
Number of contacts as normally closed contact
1
Forced opening
Number of safety auxiliary contacts
0
Alignment of the control element
Roller cam straight
Output electronic
Type of interface for safety communication
None
With status indication
Rated operation current Ie at DC-13, 230 V
0.27A
Type of control element
Roller cam
Type of electric connection
Cable entry PG
Explosion safety category for dust
None
Explosion safety category for gas
None
Coating housing
Other
Switching function
Quick-break switch
Material housing
Plastic
Suitable for safety functions
Degree of protection (IP)
IP66/IP67
Construction type housing
Special construction
Ambient temperature during operating
-25 .. 70°C
From same serie
We use cookies to enhance your experience.