Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50047
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Output electronic
No
Number of safety auxiliary contacts
0
Type of interface for safety communication
None
Type of control element
Roller lever
Coating housing
Other
Forced opening
Yes
Alignment of the control element
Other
Material housing
Plastic
With status indication
No
Length of sensor
30mm
Explosion safety category for dust
None
Switching function
Quick-break switch
Switching function latching
No
Number of contacts as change-over contact
0
Type of interface
None
Number of contacts as normally closed contact
1
Number of contacts as normally open contact
1
Rated operation current Ie at AC-15, 230 V
3A
Rated operation current Ie at DC-13, 230 V
0.27A
Explosion safety category for gas
None
Ambient temperature during operating
-25 - 70°C
Suitable for safety functions
No
Degree of protection (IP)
IP66/IP67
Type of electric connection
Cable entry metrical
Height of sensor
65mm
Width sensor
31mm
Construction type housing
Cuboid
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XCKP2128P16

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50047
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Output electronic
Number of safety auxiliary contacts
0
Type of interface for safety communication
None
Type of control element
Roller lever
Coating housing
Other
Forced opening
Alignment of the control element
Other
Material housing
Plastic
With status indication
Length of sensor
30mm
Explosion safety category for dust
None
Switching function
Quick-break switch
Switching function latching
Number of contacts as change-over contact
0
Type of interface
None
Number of contacts as normally closed contact
1
Number of contacts as normally open contact
1
Rated operation current Ie at AC-15, 230 V
3A
Rated operation current Ie at DC-13, 230 V
0.27A
Explosion safety category for gas
None
Ambient temperature during operating
-25 .. 70°C
Suitable for safety functions
Degree of protection (IP)
IP66/IP67
Type of electric connection
Cable entry metrical
Height of sensor
65mm
Width sensor
31mm
Construction type housing
Cuboid
From same serie