Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50047
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at DC-13, 24 V
0A
Output electronic
No
Coating housing
Other
Type of electric connection
Cable entry PG
Rated operation current Ie at DC-13, 230 V
0.27A
Number of contacts as change-over contact
0
Number of contacts as normally open contact
1
Switching function latching
No
Number of safety auxiliary contacts
0
Number of contacts as normally closed contact
1
Switching function
Quick-break switch
Rated operation current Ie at AC-15, 230 V
3A
Type of interface for safety communication
None
Material housing
Plastic
Alignment of the control element
Other
Type of interface
None
Construction type housing
Cuboid
With status indication
No
Forced opening
Yes
Height of sensor
65mm
Width sensor
31mm
Length of sensor
30mm
Degree of protection (IP)
IP66/IP67
Explosion safety category for gas
None
Type of control element
Roller lever
Suitable for safety functions
No
Ambient temperature during operating
-25 - 70°C
Explosion safety category for dust
None
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XCKP2118G11

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50047
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at DC-13, 24 V
0A
Output electronic
Coating housing
Other
Type of electric connection
Cable entry PG
Rated operation current Ie at DC-13, 230 V
0.27A
Number of contacts as change-over contact
0
Number of contacts as normally open contact
1
Switching function latching
Number of safety auxiliary contacts
0
Number of contacts as normally closed contact
1
Switching function
Quick-break switch
Rated operation current Ie at AC-15, 230 V
3A
Type of interface for safety communication
None
Material housing
Plastic
Alignment of the control element
Other
Type of interface
None
Construction type housing
Cuboid
With status indication
Forced opening
Height of sensor
65mm
Width sensor
31mm
Length of sensor
30mm
Degree of protection (IP)
IP66/IP67
Explosion safety category for gas
None
Type of control element
Roller lever
Suitable for safety functions
Ambient temperature during operating
-25 .. 70°C
Explosion safety category for dust
None
From same serie