Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50047
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at DC-13, 24 V
0A
Width sensor
31mm
Rated operation current Ie at AC-15, 230 V
3A
Height of sensor
65mm
Rated operation current Ie at DC-13, 230 V
0.27A
Material housing
Plastic
Number of contacts as change-over contact
0
Type of interface for safety communication
None
Number of safety auxiliary contacts
0
Number of contacts as normally closed contact
1
Number of contacts as normally open contact
1
Forced opening
Yes
Switching function latching
No
Type of electric connection
Cable entry PG
Ambient temperature during operating
-25 - 70°C
Length of sensor
30mm
Explosion safety category for gas
None
Type of interface
None
With status indication
No
Explosion safety category for dust
None
Alignment of the control element
Other
Degree of protection (IP)
IP66/IP67
Suitable for safety functions
No
Type of control element
Plunger
Switching function
Quick-break switch
Coating housing
Other
Construction type housing
Cuboid
Output electronic
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XCKP2110G11

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50047
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at DC-13, 24 V
0A
Width sensor
31mm
Rated operation current Ie at AC-15, 230 V
3A
Height of sensor
65mm
Rated operation current Ie at DC-13, 230 V
0.27A
Material housing
Plastic
Number of contacts as change-over contact
0
Type of interface for safety communication
None
Number of safety auxiliary contacts
0
Number of contacts as normally closed contact
1
Number of contacts as normally open contact
1
Forced opening
Switching function latching
Type of electric connection
Cable entry PG
Ambient temperature during operating
-25 .. 70°C
Length of sensor
30mm
Explosion safety category for gas
None
Type of interface
None
With status indication
Explosion safety category for dust
None
Alignment of the control element
Other
Degree of protection (IP)
IP66/IP67
Suitable for safety functions
Type of control element
Plunger
Switching function
Quick-break switch
Coating housing
Other
Construction type housing
Cuboid
Output electronic
From same serie
We use cookies to enhance your experience.