Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50047
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at DC-13, 24 V
0A
Switching function
Quick-break switch
Type of interface
None
Number of safety auxiliary contacts
0
Construction type housing
Cuboid
Length of sensor
30mm
Type of interface for safety communication
None
Switching function latching
No
Output electronic
No
Height of sensor
65mm
Number of contacts as normally closed contact
1
Rated operation current Ie at DC-13, 230 V
0.27A
Width sensor
31mm
Number of contacts as change-over contact
0
Number of contacts as normally open contact
1
Coating housing
Other
Forced opening
Yes
Ambient temperature during operating
-25 - 70°C
Explosion safety category for dust
None
Suitable for safety functions
No
Type of control element
Roller cam
Explosion safety category for gas
None
Type of electric connection
Connector M12
With status indication
No
Degree of protection (IP)
IP66/IP67
Rated operation current Ie at AC-15, 230 V
3A
Alignment of the control element
Roller cam straight
Material housing
Plastic
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XCKP2102M12

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50047
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at DC-13, 24 V
0A
Switching function
Quick-break switch
Type of interface
None
Number of safety auxiliary contacts
0
Construction type housing
Cuboid
Length of sensor
30mm
Type of interface for safety communication
None
Switching function latching
Output electronic
Height of sensor
65mm
Number of contacts as normally closed contact
1
Rated operation current Ie at DC-13, 230 V
0.27A
Width sensor
31mm
Number of contacts as change-over contact
0
Number of contacts as normally open contact
1
Coating housing
Other
Forced opening
Ambient temperature during operating
-25 .. 70°C
Explosion safety category for dust
None
Suitable for safety functions
Type of control element
Roller cam
Explosion safety category for gas
None
Type of electric connection
Connector M12
With status indication
Degree of protection (IP)
IP66/IP67
Rated operation current Ie at AC-15, 230 V
3A
Alignment of the control element
Roller cam straight
Material housing
Plastic
From same serie