Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50047
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Width sensor
30mm
Number of contacts as normally closed contact
1
Rated operation current Ie at DC-13, 230 V
0.1A
Number of contacts as change-over contact
0
Number of safety auxiliary contacts
0
Type of interface for safety communication
None
Type of control element
Spring-rod
Alignment of the control element
Other
Material housing
Plastic
Output electronic
No
Ambient temperature during operating
-25 - 70°C
With status indication
No
Construction type housing
Cuboid
Height of sensor
197mm
Switching function
Quick-break switch
Type of interface
None
Switching function latching
No
Forced opening
No
Number of contacts as normally open contact
1
Length of sensor
30mm
Coating housing
Other
Suitable for safety functions
No
Explosion safety category for dust
None
Degree of protection (IP)
IP65
Type of electric connection
Cable entry metrical
Rated operation current Ie at AC-15, 230 V
3A
Explosion safety category for gas
None
From same serie
XCKN2106P20

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50047
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Width sensor
30mm
Number of contacts as normally closed contact
1
Rated operation current Ie at DC-13, 230 V
0.1A
Number of contacts as change-over contact
0
Number of safety auxiliary contacts
0
Type of interface for safety communication
None
Type of control element
Spring-rod
Alignment of the control element
Other
Material housing
Plastic
Output electronic
Ambient temperature during operating
-25 .. 70°C
With status indication
Construction type housing
Cuboid
Height of sensor
197mm
Switching function
Quick-break switch
Type of interface
None
Switching function latching
Forced opening
Number of contacts as normally open contact
1
Length of sensor
30mm
Coating housing
Other
Suitable for safety functions
Explosion safety category for dust
None
Degree of protection (IP)
IP65
Type of electric connection
Cable entry metrical
Rated operation current Ie at AC-15, 230 V
3A
Explosion safety category for gas
None