Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
Other
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Switching function latching
No
Number of safety auxiliary contacts
0
Output electronic
No
Explosion safety category for gas
None
Type of interface
None
With status indication
No
Length of sensor
59mm
Type of control element
Other
Width sensor
200mm
Height of sensor
118mm
Rated operation current Ie at AC-15, 230 V
3A
Forced opening
Yes
Type of interface for safety communication
None
Type of electric connection
Cable entry PG
Construction type housing
Special construction
Number of contacts as normally open contact
0
Number of contacts as normally closed contact
4
Rated operation current Ie at DC-13, 230 V
0.55A
Number of contacts as change-over contact
0
Explosion safety category for dust
None
Switching function
Other
Material housing
Metal
Coating housing
Other
Ambient temperature during operating
-25 - 70°C
Suitable for safety functions
No
Alignment of the control element
Other
Degree of protection (IP)
IP66/IP67
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XCKMR54D1

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
Other
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Switching function latching
Number of safety auxiliary contacts
0
Output electronic
Explosion safety category for gas
None
Type of interface
None
With status indication
Length of sensor
59mm
Type of control element
Other
Width sensor
200mm
Height of sensor
118mm
Rated operation current Ie at AC-15, 230 V
3A
Forced opening
Type of interface for safety communication
None
Type of electric connection
Cable entry PG
Construction type housing
Special construction
Number of contacts as normally open contact
0
Number of contacts as normally closed contact
4
Rated operation current Ie at DC-13, 230 V
0.55A
Number of contacts as change-over contact
0
Explosion safety category for dust
None
Switching function
Other
Material housing
Metal
Coating housing
Other
Ambient temperature during operating
-25 .. 70°C
Suitable for safety functions
Alignment of the control element
Other
Degree of protection (IP)
IP66/IP67
From same serie