Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
Other
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 230 V
0.27A
Length of sensor
30mm
Switching function
Quick-break switch
Rated operation current Ie at AC-15, 230 V
3A
Width sensor
52mm
Number of safety auxiliary contacts
1
Forced opening
Yes
Construction type housing
Cuboid
Coating housing
Other
With status indication
No
Output electronic
No
Alignment of the control element
Roller cam straight
Number of contacts as normally open contact
1
Explosion safety category for dust
None
Number of contacts as normally closed contact
1
Explosion safety category for gas
None
Type of control element
Roller cam
Material housing
Metal
Height of sensor
72mm
Type of electric connection
Other
Type of interface for safety communication
None
Suitable for safety functions
Yes
Ambient temperature during operating
-25 - 70°C
Number of contacts as change-over contact
0
Type of interface
None
Switching function latching
No
Degree of protection (IP)
IP66/IP67
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XCKL102

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
Other
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 230 V
0.27A
Length of sensor
30mm
Switching function
Quick-break switch
Rated operation current Ie at AC-15, 230 V
3A
Width sensor
52mm
Number of safety auxiliary contacts
1
Forced opening
Construction type housing
Cuboid
Coating housing
Other
With status indication
Output electronic
Alignment of the control element
Roller cam straight
Number of contacts as normally open contact
1
Explosion safety category for dust
None
Number of contacts as normally closed contact
1
Explosion safety category for gas
None
Type of control element
Roller cam
Material housing
Metal
Height of sensor
72mm
Type of electric connection
Other
Type of interface for safety communication
None
Suitable for safety functions
Ambient temperature during operating
-25 .. 70°C
Number of contacts as change-over contact
0
Type of interface
None
Switching function latching
Degree of protection (IP)
IP66/IP67
From same serie
We use cookies to enhance your experience.