Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50041
Rated operation current Ie at DC-13, 125 V
0A
Width sensor
40mm
Rated operation current Ie at AC-15, 230 V
3A
Length of sensor
44mm
Rated operation current Ie at DC-13, 230 V
0.27A
Switching function
Other
Output electronic
No
Forced opening
Yes
Switching function latching
No
Number of safety auxiliary contacts
0
Rated operation current Ie at AC-15, 125 V
3A
Number of contacts as normally open contact
1
Number of contacts as normally closed contact
1
Height of sensor
77mm
Type of interface for safety communication
None
Number of contacts as change-over contact
0
Type of interface
None
With status indication
No
Material housing
Metal
Construction type housing
Cuboid
Alignment of the control element
Other
Type of control element
Plunger
Type of electric connection
Cable entry metrical
Coating housing
Other
Explosion safety category for dust
None
Explosion safety category for gas
None
Degree of protection (IP)
IP66/IP67
Ambient temperature during operating
-25 - 70°C
Suitable for safety functions
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XCKJ561H29

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50041
Rated operation current Ie at DC-13, 125 V
0A
Width sensor
40mm
Rated operation current Ie at AC-15, 230 V
3A
Length of sensor
44mm
Rated operation current Ie at DC-13, 230 V
0.27A
Switching function
Other
Output electronic
Forced opening
Switching function latching
Number of safety auxiliary contacts
0
Rated operation current Ie at AC-15, 125 V
3A
Number of contacts as normally open contact
1
Number of contacts as normally closed contact
1
Height of sensor
77mm
Type of interface for safety communication
None
Number of contacts as change-over contact
0
Type of interface
None
With status indication
Material housing
Metal
Construction type housing
Cuboid
Alignment of the control element
Other
Type of control element
Plunger
Type of electric connection
Cable entry metrical
Coating housing
Other
Explosion safety category for dust
None
Explosion safety category for gas
None
Degree of protection (IP)
IP66/IP67
Ambient temperature during operating
-25 .. 70°C
Suitable for safety functions
From same serie