Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50041
Rated operation current Ie at DC-13, 125 V
0A
Width sensor
40mm
Switching function
Other
Rated operation current Ie at DC-13, 230 V
0.27A
Height of sensor
77mm
Switching function latching
No
Number of contacts as normally closed contact
1
Length of sensor
44mm
Type of interface for safety communication
None
Material housing
Metal
Type of electric connection
Cable entry PG
Construction type housing
Cuboid
Forced opening
Yes
Type of control element
Adjustable rotary lever
Suitable for safety functions
No
Explosion safety category for gas
None
Ambient temperature during operating
-25 - 70°C
With status indication
No
Degree of protection (IP)
IP66/IP67
Alignment of the control element
Other
Number of contacts as normally open contact
1
Rated operation current Ie at AC-15, 125 V
3A
Output electronic
No
Rated operation current Ie at AC-15, 230 V
3A
Type of interface
None
Coating housing
Other
Explosion safety category for dust
None
Number of safety auxiliary contacts
0
Number of contacts as change-over contact
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XCKJ50559

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50041
Rated operation current Ie at DC-13, 125 V
0A
Width sensor
40mm
Switching function
Other
Rated operation current Ie at DC-13, 230 V
0.27A
Height of sensor
77mm
Switching function latching
Number of contacts as normally closed contact
1
Length of sensor
44mm
Type of interface for safety communication
None
Material housing
Metal
Type of electric connection
Cable entry PG
Construction type housing
Cuboid
Forced opening
Type of control element
Adjustable rotary lever
Suitable for safety functions
Explosion safety category for gas
None
Ambient temperature during operating
-25 .. 70°C
With status indication
Degree of protection (IP)
IP66/IP67
Alignment of the control element
Other
Number of contacts as normally open contact
1
Rated operation current Ie at AC-15, 125 V
3A
Output electronic
Rated operation current Ie at AC-15, 230 V
3A
Type of interface
None
Coating housing
Other
Explosion safety category for dust
None
Number of safety auxiliary contacts
0
Number of contacts as change-over contact
0
From same serie