Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50041
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at AC-15, 125 V
3A
Height of sensor
77mm
Width sensor
40mm
Rated operation current Ie at DC-13, 230 V
0.27A
Switching function
Other
Rated operation current Ie at AC-15, 230 V
3A
Number of contacts as normally closed contact
1
Switching function latching
No
Construction type housing
Cuboid
Type of electric connection
Cable entry PG
Length of sensor
44mm
Material housing
Metal
Type of control element
Roller lever
Type of interface for safety communication
None
Output electronic
No
Number of safety auxiliary contacts
0
Forced opening
Yes
Number of contacts as change-over contact
0
Number of contacts as normally open contact
1
Type of interface
None
With status indication
No
Coating housing
Other
Explosion safety category for dust
None
Degree of protection (IP)
IP66/IP67
Alignment of the control element
Other
Explosion safety category for gas
None
Ambient temperature during operating
-25 - 70°C
Suitable for safety functions
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XCKJ50511

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50041
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at AC-15, 125 V
3A
Height of sensor
77mm
Width sensor
40mm
Rated operation current Ie at DC-13, 230 V
0.27A
Switching function
Other
Rated operation current Ie at AC-15, 230 V
3A
Number of contacts as normally closed contact
1
Switching function latching
Construction type housing
Cuboid
Type of electric connection
Cable entry PG
Length of sensor
44mm
Material housing
Metal
Type of control element
Roller lever
Type of interface for safety communication
None
Output electronic
Number of safety auxiliary contacts
0
Forced opening
Number of contacts as change-over contact
0
Number of contacts as normally open contact
1
Type of interface
None
With status indication
Coating housing
Other
Explosion safety category for dust
None
Degree of protection (IP)
IP66/IP67
Alignment of the control element
Other
Explosion safety category for gas
None
Ambient temperature during operating
-25 .. 70°C
Suitable for safety functions
From same serie
We use cookies to enhance your experience.