Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50041
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at AC-15, 125 V
3A
Height of sensor
84mm
Rated operation current Ie at DC-13, 230 V
0.27A
Rated operation current Ie at AC-15, 230 V
3A
Switching function
Quick-break switch
Forced opening
Yes
Length of sensor
36mm
Switching function latching
No
Width sensor
40mm
Type of interface for safety communication
None
Number of contacts as normally open contact
1
Coating housing
Other
Number of safety auxiliary contacts
0
Ambient temperature during operating
-25 - 70°C
Explosion safety category for gas
None
Suitable for safety functions
No
With status indication
No
Construction type housing
Cuboid
Number of contacts as change-over contact
1
Type of electric connection
Cable entry metrical
Material housing
Metal
Type of interface
None
Output electronic
No
Explosion safety category for dust
None
Alignment of the control element
Roller cam straight
Type of control element
Roller cam
Degree of protection (IP)
IP66/IP67
Number of contacts as normally closed contact
1
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XCKJ1167H29

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50041
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at AC-15, 125 V
3A
Height of sensor
84mm
Rated operation current Ie at DC-13, 230 V
0.27A
Rated operation current Ie at AC-15, 230 V
3A
Switching function
Quick-break switch
Forced opening
Length of sensor
36mm
Switching function latching
Width sensor
40mm
Type of interface for safety communication
None
Number of contacts as normally open contact
1
Coating housing
Other
Number of safety auxiliary contacts
0
Ambient temperature during operating
-25 .. 70°C
Explosion safety category for gas
None
Suitable for safety functions
With status indication
Construction type housing
Cuboid
Number of contacts as change-over contact
1
Type of electric connection
Cable entry metrical
Material housing
Metal
Type of interface
None
Output electronic
Explosion safety category for dust
None
Alignment of the control element
Roller cam straight
Type of control element
Roller cam
Degree of protection (IP)
IP66/IP67
Number of contacts as normally closed contact
1
From same serie
We use cookies to enhance your experience.