Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50041
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Width sensor
40mm
Length of sensor
62mm
Height of sensor
150mm
Switching function
Quick-break switch
Rated operation current Ie at AC-15, 230 V
3A
Number of contacts as normally open contact
1
Number of contacts as change-over contact
0
Number of contacts as normally closed contact
1
Output electronic
No
Type of control element
Roller lever
Material housing
Metal
Coating housing
Other
Type of electric connection
Other
Explosion safety category for dust
None
Type of interface for safety communication
None
Alignment of the control element
Other
Explosion safety category for gas
None
Type of interface
None
Number of safety auxiliary contacts
0
With status indication
No
Rated operation current Ie at DC-13, 230 V
0.27A
Switching function latching
No
Forced opening
Yes
Construction type housing
Cuboid
Suitable for safety functions
No
Ambient temperature during operating
-25 - 70°C
Degree of protection (IP)
IP66/IP67
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XCKJ10513A

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50041
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Width sensor
40mm
Length of sensor
62mm
Height of sensor
150mm
Switching function
Quick-break switch
Rated operation current Ie at AC-15, 230 V
3A
Number of contacts as normally open contact
1
Number of contacts as change-over contact
0
Number of contacts as normally closed contact
1
Output electronic
Type of control element
Roller lever
Material housing
Metal
Coating housing
Other
Type of electric connection
Other
Explosion safety category for dust
None
Type of interface for safety communication
None
Alignment of the control element
Other
Explosion safety category for gas
None
Type of interface
None
Number of safety auxiliary contacts
0
With status indication
Rated operation current Ie at DC-13, 230 V
0.27A
Switching function latching
Forced opening
Construction type housing
Cuboid
Suitable for safety functions
Ambient temperature during operating
-25 .. 70°C
Degree of protection (IP)
IP66/IP67
From same serie