Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50047
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at AC-15, 230 V
1.5A
Length of sensor
30mm
Width sensor
31mm
Rated operation current Ie at DC-13, 230 V
0.1A
Output electronic
No
Height of sensor
65mm
Switching function
Quick-break switch
Coating housing
Other
Switching function latching
No
Forced opening
Yes
Number of contacts as change-over contact
0
Number of safety auxiliary contacts
0
Construction type housing
Cuboid
Material housing
Metal
Type of control element
Plunger
Number of contacts as normally closed contact
2
Alignment of the control element
Other
Explosion safety category for dust
Other
Type of interface for safety communication
None
Number of contacts as normally open contact
1
Type of interface
None
Ambient temperature during operating
-20 - 60°C
Explosion safety category for gas
None
Type of electric connection
Other
With status indication
No
Degree of protection (IP)
IP67K
Suitable for safety functions
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
Code: 1718219
XCKD39H0P16EX

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50047
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at AC-15, 230 V
1.5A
Length of sensor
30mm
Width sensor
31mm
Rated operation current Ie at DC-13, 230 V
0.1A
Output electronic
Height of sensor
65mm
Switching function
Quick-break switch
Coating housing
Other
Switching function latching
Forced opening
Number of contacts as change-over contact
0
Number of safety auxiliary contacts
0
Construction type housing
Cuboid
Material housing
Metal
Type of control element
Plunger
Number of contacts as normally closed contact
2
Alignment of the control element
Other
Explosion safety category for dust
Other
Type of interface for safety communication
None
Number of contacts as normally open contact
1
Type of interface
None
Ambient temperature during operating
-20 .. 60°C
Explosion safety category for gas
None
Type of electric connection
Other
With status indication
Degree of protection (IP)
IP67K
Suitable for safety functions
From same serie