Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50047
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at AC-15, 125 V
0A
Width sensor
31mm
Rated operation current Ie at AC-15, 230 V
3A
Forced opening
Yes
Number of safety auxiliary contacts
0
Number of contacts as normally open contact
1
Number of contacts as change-over contact
0
Ambient temperature during operating
-25 - 70°C
Construction type housing
Cuboid
With status indication
No
Rated operation current Ie at DC-13, 230 V
0.27A
Type of electric connection
Cable entry PG
Height of sensor
158mm
Output electronic
No
Number of contacts as normally closed contact
1
Length of sensor
40mm
Switching function
Slow-action switch and quick-break switch
Type of interface
None
Material housing
Metal
Coating housing
Other
Degree of protection (IP)
IP66/IP67
Alignment of the control element
Other
Type of interface for safety communication
None
Switching function latching
No
Explosion safety category for gas
None
Type of control element
Roller lever
Explosion safety category for dust
None
Suitable for safety functions
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XCKD2545G11

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50047
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at AC-15, 125 V
0A
Width sensor
31mm
Rated operation current Ie at AC-15, 230 V
3A
Forced opening
Number of safety auxiliary contacts
0
Number of contacts as normally open contact
1
Number of contacts as change-over contact
0
Ambient temperature during operating
-25 .. 70°C
Construction type housing
Cuboid
With status indication
Rated operation current Ie at DC-13, 230 V
0.27A
Type of electric connection
Cable entry PG
Height of sensor
158mm
Output electronic
Number of contacts as normally closed contact
1
Length of sensor
40mm
Switching function
Slow-action switch and quick-break switch
Type of interface
None
Material housing
Metal
Coating housing
Other
Degree of protection (IP)
IP66/IP67
Alignment of the control element
Other
Type of interface for safety communication
None
Switching function latching
Explosion safety category for gas
None
Type of control element
Roller lever
Explosion safety category for dust
None
Suitable for safety functions
From same serie