Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Rated operation current Ie at AC-15, 125 V
0A
Housing according to norm
DIN EN 50047
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 230 V
3A
Width sensor
31mm
Switching function
Quick-break switch
Rated operation current Ie at DC-13, 230 V
0.27A
Switching function latching
No
Forced opening
Yes
Number of contacts as normally closed contact
1
Number of safety auxiliary contacts
0
Number of contacts as normally open contact
1
Type of interface for safety communication
None
Type of interface
None
Type of control element
Roller cam
Construction type housing
Cuboid
Material housing
Metal
Type of electric connection
Cable entry metrical
Degree of protection (IP)
IP66/IP67
Coating housing
Other
Explosion safety category for dust
None
With status indication
No
Explosion safety category for gas
None
Length of sensor
30mm
Output electronic
No
Number of contacts as change-over contact
0
Suitable for safety functions
No
Height of sensor
65mm
Ambient temperature during operating
-25 - 70°C
Alignment of the control element
Roller cam straight
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XCKD21H2P16

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Rated operation current Ie at AC-15, 125 V
0A
Housing according to norm
DIN EN 50047
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 230 V
3A
Width sensor
31mm
Switching function
Quick-break switch
Rated operation current Ie at DC-13, 230 V
0.27A
Switching function latching
Forced opening
Number of contacts as normally closed contact
1
Number of safety auxiliary contacts
0
Number of contacts as normally open contact
1
Type of interface for safety communication
None
Type of interface
None
Type of control element
Roller cam
Construction type housing
Cuboid
Material housing
Metal
Type of electric connection
Cable entry metrical
Degree of protection (IP)
IP66/IP67
Coating housing
Other
Explosion safety category for dust
None
With status indication
Explosion safety category for gas
None
Length of sensor
30mm
Output electronic
Number of contacts as change-over contact
0
Suitable for safety functions
Height of sensor
65mm
Ambient temperature during operating
-25 .. 70°C
Alignment of the control element
Roller cam straight