Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Rated operation current Ie at AC-15, 125 V
0A
Housing according to norm
DIN EN 50047
Rated operation current Ie at DC-13, 24 V
0A
Width sensor
31mm
Rated operation current Ie at DC-13, 230 V
0.27A
Height of sensor
65mm
Number of contacts as normally closed contact
1
Length of sensor
30mm
Output electronic
No
Number of contacts as change-over contact
0
Construction type housing
Cuboid
Suitable for safety functions
No
Type of interface for safety communication
None
Alignment of the control element
Roller cam straight
Coating housing
Other
Material housing
Metal
Type of electric connection
Cable entry metrical
Degree of protection (IP)
IP66/IP67
Ambient temperature during operating
-25 - 70°C
Number of contacts as normally open contact
1
With status indication
No
Type of interface
None
Switching function latching
No
Explosion safety category for gas
None
Switching function
Quick-break switch
Number of safety auxiliary contacts
0
Type of control element
Roller cam
Explosion safety category for dust
None
Forced opening
Yes
Rated operation current Ie at AC-15, 230 V
3A
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XCKD2128P16

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Rated operation current Ie at AC-15, 125 V
0A
Housing according to norm
DIN EN 50047
Rated operation current Ie at DC-13, 24 V
0A
Width sensor
31mm
Rated operation current Ie at DC-13, 230 V
0.27A
Height of sensor
65mm
Number of contacts as normally closed contact
1
Length of sensor
30mm
Output electronic
Number of contacts as change-over contact
0
Construction type housing
Cuboid
Suitable for safety functions
Type of interface for safety communication
None
Alignment of the control element
Roller cam straight
Coating housing
Other
Material housing
Metal
Type of electric connection
Cable entry metrical
Degree of protection (IP)
IP66/IP67
Ambient temperature during operating
-25 .. 70°C
Number of contacts as normally open contact
1
With status indication
Type of interface
None
Switching function latching
Explosion safety category for gas
None
Switching function
Quick-break switch
Number of safety auxiliary contacts
0
Type of control element
Roller cam
Explosion safety category for dust
None
Forced opening
Rated operation current Ie at AC-15, 230 V
3A