Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Rated operation current Ie at AC-15, 125 V
0A
Housing according to norm
DIN EN 50047
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at DC-13, 230 V
0.27A
Length of sensor
30mm
Width sensor
31mm
Switching function latching
No
Height of sensor
65mm
Rated operation current Ie at AC-15, 230 V
3A
Number of safety auxiliary contacts
0
Switching function
Quick-break switch
Forced opening
Yes
Explosion safety category for dust
None
Number of contacts as normally open contact
1
Output electronic
No
Construction type housing
Cuboid
Type of interface for safety communication
None
Number of contacts as change-over contact
0
Number of contacts as normally closed contact
1
Alignment of the control element
Other
Type of interface
None
Coating housing
Other
With status indication
No
Type of control element
Roller lever
Suitable for safety functions
No
Type of electric connection
Connector M12
Material housing
Metal
Explosion safety category for gas
None
Degree of protection (IP)
IP66/IP67
Ambient temperature during operating
-25 - 70°C
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XCKD2118M12

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Rated operation current Ie at AC-15, 125 V
0A
Housing according to norm
DIN EN 50047
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at DC-13, 230 V
0.27A
Length of sensor
30mm
Width sensor
31mm
Switching function latching
Height of sensor
65mm
Rated operation current Ie at AC-15, 230 V
3A
Number of safety auxiliary contacts
0
Switching function
Quick-break switch
Forced opening
Explosion safety category for dust
None
Number of contacts as normally open contact
1
Output electronic
Construction type housing
Cuboid
Type of interface for safety communication
None
Number of contacts as change-over contact
0
Number of contacts as normally closed contact
1
Alignment of the control element
Other
Type of interface
None
Coating housing
Other
With status indication
Type of control element
Roller lever
Suitable for safety functions
Type of electric connection
Connector M12
Material housing
Metal
Explosion safety category for gas
None
Degree of protection (IP)
IP66/IP67
Ambient temperature during operating
-25 .. 70°C
From same serie
We use cookies to enhance your experience.