Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Degree of protection (IP)
IP65
Type of control element
Roller cam
Material housing
Metal
Ambient temperature during operating
-25 - 70°C
Number of contacts as normally closed contact
0
Number of contacts as normally open contact
0
Number of contacts as change-over contact
1
Type of electric connection
Cable entry PG
Explosion safety category for dust
None
Length of sensor
41mm
Height of sensor
81mm
Width sensor
40mm
Construction type housing
Cuboid
Diameter sensor
0mm
Type of interface
None
Type of interface for safety communication
None
Coating housing
Other
Suitable for safety functions
No
Explosion safety category for gas
None
Rated operation current Ie at AC-15, 230 V
3A
Rated operation current Ie at DC-13, 125 V
0A
Number of safety auxiliary contacts
0
With status indication
No
Rated operation current Ie at AC-15, 24 V
0A
Rated operation current Ie at AC-15, 125 V
3A
Forced opening
No
Output electronic
No
Switching function
Quick-break switch
Alignment of the control element
Roller cam straight
Housing according to norm
Other
Rated operation current Ie at DC-13, 230 V
0.27A
Rated operation current Ie at DC-13, 24 V
0A
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XC2JC162

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Degree of protection (IP)
IP65
Type of control element
Roller cam
Material housing
Metal
Ambient temperature during operating
-25 .. 70°C
Number of contacts as normally closed contact
0
Number of contacts as normally open contact
0
Number of contacts as change-over contact
1
Type of electric connection
Cable entry PG
Explosion safety category for dust
None
Length of sensor
41mm
Height of sensor
81mm
Width sensor
40mm
Construction type housing
Cuboid
Diameter sensor
0mm
Type of interface
None
Type of interface for safety communication
None
Coating housing
Other
Suitable for safety functions
Explosion safety category for gas
None
Rated operation current Ie at AC-15, 230 V
3A
Rated operation current Ie at DC-13, 125 V
0A
Number of safety auxiliary contacts
0
With status indication
Rated operation current Ie at AC-15, 24 V
0A
Rated operation current Ie at AC-15, 125 V
3A
Forced opening
Output electronic
Switching function
Quick-break switch
Alignment of the control element
Roller cam straight
Housing according to norm
Other
Rated operation current Ie at DC-13, 230 V
0.27A
Rated operation current Ie at DC-13, 24 V
0A
From same serie