- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Max. rated operation voltage Ue AC
690V
Rated operating voltage
690 - 690V
Version as emergency stop installation
Yes
Version as maintenance-/service switch
No
Version as main switch
Yes
Version as reversing switch
No
Switching power at 400 V
18.5kW
Rated short-time withstand current lcw
0.48kA
Number of switches
1
Version as safety switch
No
Number of auxiliary contacts as change-over contact
0
Rated permanent current at AC-21, 400 V
32A
Motor drive integrated
No
Rated operation power at AC-23, 400 V
15kW
Conditioned rated short-circuit current Iq
10kA
Rated permanent current Iu
32A
Motor drive optional
No
Number of auxiliary contacts as normally open contact
0
Rated permanent current at AC-23, 400 V
29A
Number of poles
3
Device construction
Complete device in housing
Number of auxiliary contacts as normally closed contact
0
Suitable for floor mounting
No
Suitable for front mounting 4-hole
Yes
Suitable for intermediate mounting
No
Suitable for front mounting centre
No
Suitable for distribution board installation
No
Rated operation power at AC-3, 400 V
11kW
Voltage release optional
No
Type of control element
Turn button
Colour control element
Red
Type of electrical connection of main circuit
Screw connection
Interlockable
Yes
Degree of protection (IP), front side
IP55
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
VCFN40GE
Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Max. rated operation voltage Ue AC
690V
Rated operating voltage
690 .. 690V
Version as emergency stop installation
Version as maintenance-/service switch
Version as main switch
Version as reversing switch
Switching power at 400 V
18.5kW
Rated short-time withstand current lcw
0.48kA
Number of switches
1
Version as safety switch
Number of auxiliary contacts as change-over contact
0
Rated permanent current at AC-21, 400 V
32A
Motor drive integrated
Rated operation power at AC-23, 400 V
15kW
Conditioned rated short-circuit current Iq
10kA
Rated permanent current Iu
32A
Motor drive optional
Number of auxiliary contacts as normally open contact
0
Rated permanent current at AC-23, 400 V
29A
Number of poles
3
Device construction
Complete device in housing
Number of auxiliary contacts as normally closed contact
0
Suitable for floor mounting
Suitable for front mounting 4-hole
Suitable for intermediate mounting
Suitable for front mounting centre
Suitable for distribution board installation
Rated operation power at AC-3, 400 V
11kW
Voltage release optional
Type of control element
Turn button
Colour control element
Red
Type of electrical connection of main circuit
Screw connection
Interlockable
Degree of protection (IP), front side
IP55