Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Version as main switch
Yes
Version as safety switch
No
Version as maintenance-/service switch
No
Max. rated operation voltage Ue AC
690V
Rated permanent current Iu
20A
Version as reversing switch
No
Rated permanent current at AC-21, 400 V
20A
Rated operation power at AC-3, 400 V
5.5kW
Conditioned rated short-circuit current Iq
10kA
Number of poles
3
Switching power at 400 V
11kW
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
0
Rated operating voltage
690 - 690V
Rated short-time withstand current lcw
0.3kA
Rated operation power at AC-23, 400 V
7.5kW
Motor drive integrated
No
Number of auxiliary contacts as normally closed contact
0
Motor drive optional
No
Number of switches
1
Rated permanent current at AC-23, 400 V
57A
Voltage release optional
No
Version as emergency stop installation
Yes
Device construction
Complete device in housing
Suitable for floor mounting
No
Suitable for distribution board installation
No
Suitable for intermediate mounting
No
Suitable for front mounting 4-hole
Yes
Type of electrical connection of main circuit
Screw connection
Type of control element
Turn button
Suitable for front mounting centre
No
Colour control element
Red
Interlockable
Yes
Degree of protection (IP), front side
IP65
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
VCF0GE
Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Version as main switch
Version as safety switch
Version as maintenance-/service switch
Max. rated operation voltage Ue AC
690V
Rated permanent current Iu
20A
Version as reversing switch
Rated permanent current at AC-21, 400 V
20A
Rated operation power at AC-3, 400 V
5.5kW
Conditioned rated short-circuit current Iq
10kA
Number of poles
3
Switching power at 400 V
11kW
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
0
Rated operating voltage
690 .. 690V
Rated short-time withstand current lcw
0.3kA
Rated operation power at AC-23, 400 V
7.5kW
Motor drive integrated
Number of auxiliary contacts as normally closed contact
0
Motor drive optional
Number of switches
1
Rated permanent current at AC-23, 400 V
57A
Voltage release optional
Version as emergency stop installation
Device construction
Complete device in housing
Suitable for floor mounting
Suitable for distribution board installation
Suitable for intermediate mounting
Suitable for front mounting 4-hole
Type of electrical connection of main circuit
Screw connection
Type of control element
Turn button
Suitable for front mounting centre
Colour control element
Red
Interlockable
Degree of protection (IP), front side
IP65
From same serie
We use cookies to enhance your experience.